3 - 33
3 Operation
High-function General-purpose Inverter RX2 Series User’s Manual
3-8 Param
eter F
unc
tion
3
3-
8-1 Par
ameter
P
reservation
Function
3-8
Parameter Function
By configuring the soft-lock function you can prevent parameters from being changed.
Parameters
3-8-1
Parameter Preservation Function
Item
Parameter
Data
Description
Soft-lock selection
[UA-16]
00
Normal state.
Only when the soft-lock terminal [SFT] is on, data set to
[UA-17] other than [UA-16] are locked.
01
After the setting is performed, the data set to [UA-17] other
than [UA-16] are locked.
Soft-lock target
selection
[UA-17]
00
All data other than [UA-16] cannot be changed
01
Data other than [UA-16] and set frequency cannot be changed
Input terminal
selection
[CA-01] to
[CA-11]
036
[SFT]: Used when the soft-lock function is used on terminals.
Menu
Optional
device
60.00Hz
oFW
STOP
M1
H03
Output Frequency
0.00 Hz
UA-16
Soft-Lock Selection
01: Always enabled
LKS
By configuring the soft-lock function [UA-16] and [UA-17], you
can prevent parameters from being changed.
While soft-lock function is enabled, the LKS mark (Lock State
mark)
is shown on the right of parameters.
LKS
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......