6 - 37
6 Basic Parameter Settings
High-function General-purpose Inverter RX2 Series User’s Manual
6-4 F
requ
ency C
o
mm
and
Sett
ing
s
6
6-
4-9 Ca
se w
here Co
mmand Is Given with Mult
i-Ste
p Speed
A frequency command is controlled with a signal pattern by setting multiple command frequencies in
advance.
In the multi-step speed command, one can either give a binary combination of 0 (OFF) and 1 (ON) or
give a priority on certain terminals (bit operation).
In the binary operation, a frequency at maximum 16th speed with four terminals can be set. In the bit
operation, a frequency at maximum 8th speed with seven terminals can be set.
Precautions for Correct Use
• If the LCD operator [AA101]=07 is chosen in the frequency command selection, rewriting of
the main speed command [FA-01] automatically rewrites [Ab110], frequency setting of the 0th
speed.
• The frequency setting for the 1st to 15th speeds should be made in the 1st-15th speeds of
the multi-step speed function ([Ab-11]-[Ab-25]).
• With the multi-step speed function, one can set the acceleration/deceleration time individu-
ally for the frequency switching in the multi-step speed command. For details, see
Switching of Acceleration or Deceleration Time with Multi-Speed Step
• The multi-step speed function is effective only for the main speed command. Not applied to
the auxiliary speed command
• If [SET] terminal is made ON and the secondary setting function is used, [Ab210] instead of
[Ab110] becomes effective.
Parameter
6-4-9
Case where Command Is Given with Multi-Step Speed
Item
Parameters
Data
Description
Default
data
Main Speed reference
monitor
[FA-01]
Data change
depending on the
frequency com-
mand selection.
The frequency command value is shown.
-
Multispeed operation
selection
[Ab-03]
00
Binary operation, max. 16 speed modes
00
01
Bit operation, max. 8 speed modes
Multispeed-0 setting,
1st-motor
[Ab110]
0.00/Min. fre-
quency -max. fre-
quency (Hz)
0th speed of the multi-step speed
0.00
Multispeed-1to15 set-
ting
[Ab-11] to
[Ab-25]
0.00/Min. fre-
quency -max. fre-
quency (Hz)
1st-15th speeds of the multi-step speed
0.00
Multistage input deter-
mination time
[CA-55]
0 to 2000(ms)
This is the time to fix the frequency in
switching the multi-step speed.
0
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......