Regulations and standards
S8BA-24D24D
□□□
LF
18
●
Conformance to UL
▪
This product must be installed within a control panel with an internal heater or other unit to protect
against the formation of condensation (Standard mounting only).
▪
Gaps in the door to the control panel must be completely filled or covered with gaskets or other
material.
▪
For use as a UL compliant device, the specifications for S8BA-24D24D480LF are as follows:
・
Maximum input current: 20A
・
Rated output current/capacity: 16.7A/400W
▪
For use in Pollution Degree 2 Environment.
▪
Surrounding Air Temperature, 55°C.
▪
Make sure to connect the device with Class 2 output to the USB port.