S8BA-LF
12
DIN Rail (Order Separately)
Mounting Rail (Material: Aluminum)
PFP-100N
PFP-50N
Mounting Rail (Material: Aluminum)
PFP-100N2
End Plate
PFP-M
Note: 1.
If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from
aluminum abrasion.
2.
If the Unit may be subjected to sliding to either side, attach an End Plate (model PFP-M) on each side of the Unit.
Power management solutions
The following software is available as a free download from our website.
Name
Description
Conditions
Interface
Power Attendant
Lite
•
You can execute computer shutdown and UPS auto stop
when an input power problem occurs (power failure, etc.).
You can use a computer that has "Power Attendant Lite"
installed to send a script over the network to devices that do
not have shutdown software installed to log in to each device
and execute a device shutdown command.
•
You can automatically start and stop computers and the
UPS according to a preset schedule.
Windows 10 / 8.1 / 8 / 7
Windows Server 2016
Windows Server 2012 R2 / 201208
Windows Storage Server 2008
Windows Storage Server 2016
Windows Storage Server 2012 R2 / 2012
Windows Storage Server 2008 R2 / 2008
RS232C
USB
Simple Shutdown
Software
•
You can execute computer shutdown and UPS auto stop
when an input power problem occurs (power failure, etc.).
•
You can modify and recompile the source code to
incorporate a UPS management function into your Windows/
Linux
®
system.
•
Supports Windows and Linux
<For Windows>
Windows 10 / 8.1 / 8 / 7
Windows Server 2012 R2 / 2012
Windows Server 2008 R2 / 2008
Windows Server 2003R2 / 2003
Windows Vista / XP
Windows 10 IoT Enterprise LTSB
Windows Embedded Standard 7
<For Linux>
Red Hat Enterprise Linux Ver.7.x
CentOS Ver.7.x
RS232C
USB
Setting Utility
This software is used to configure UPS settings.
(Setting item examples)
Function for sending commands
Function for saving settings to a backup file
Function for restoring settings from a backup file
Function for reading UPS settings
Function for returning UPS settings to default settings
Windows 10 / 8.1 / 8 / 7
Windows Server 2012 R2 / 2012
Windows Server 2008 R2 / 2008
Windows Server 2003R2 / 2003
Windows Vista / XP
Windows 10 IoT Enterprise LTSB
Windows Embedded Standard 7
RS232C
USB
4.5
15
25
25
10
10
1,000 (500)
*
25
25
15(5)
*
35
±
0.3
7.3
±
0.15
27
±
0.15
1
*
Values in parentheses are for the PFP-50N.
4.5
15
25
25
10
10
1,000
25
25
15
1
1.5
29.2
24
27
35
±
0.3
16
1.3
4.8
35.5 35.3
1.8
1.8
10
6.2
1
50
11.5
10
M4 spring washer
M4
×
8 pan-
head screw