5-11
CHAPTER 5 Periodic Inspection
5-2-1
R6YXCH250, R6YXCH350, R6YXCH400
The following steps describe procedures and precautions when replacing the
harmonic drives of the R6YXCH250, R6YXCH350 and R6YXCH400.
For the bolt tightening torques in this work, refer to Table 5-2.
1. X-axis
1) Prepare the following tools and items.
• Harmonic grease 4B No.2
• Waste cloth (rag)
• Phillips-head screwdriver
• Hex wrench set
• Screw Lock (thread sealant)
• Ratchet handle
• Hexagonal socket set
• Extension bar
• Torque-limiting wrench
• Replacement parts (See table below.)
Replacement parts
Parts name
Type No .
OMRON Parts No.
Note
Harmonic
SHF-20-50
KN3-M2110-001
S71(JIS)
KN3-M2159-000 Top of harmonic drive
O-ring
Rubber wire diameter 1.50mm
x
Ring inner diameter 49.00mm KN3-M2143-000
For motor
Rubber wire diameter 0.99mm x Ring inner diameter 53.28mm KN3-M2144-000 Supplied with harmonic drive
2) Turn off the controller.
3) Place a sign indicating that the robot is being inspected, to keep others from
operating the controller switch.
4) Enter the safeguard enclosure.
5) Remove the base (robot pedestal) front and rear covers.
Refer to “7 Removing the Robot Covers” in Chapter 4 for removing the
covers.
WARNING
WHEN YOU REMOVE THE X-AXIS ARM INSTALLATION BOLTS
(M3×40L, 8 PIECES) IN THE NEXT STEP, THE X-AXIS ARM MAY COME
OFF CAUSING A HAZARDOUS SITUATION. BE ESPECIALLY CAREFUL
TO KEEP THE ARM FROM FALLING WHEN A HEAVY TOOL IS
ATTACHED TO THE ARM TIP.
Summary of Contents for SCARA R6Y-XC Series
Page 2: ......
Page 10: ......
Page 12: ......
Page 29: ...CHAPTER 2 Functions 1 Robot Manipulator 2 1 2 Robot Controller 2 5...
Page 30: ......
Page 36: ......
Page 38: ......
Page 51: ...3 13 CHAPTER 3 Installation Fig 3 7 Ground terminal M4 Ground terminal Ground symbol...
Page 104: ......
Page 128: ......
Page 190: ......
Page 192: ......