5-49
CHAPTER 5 Periodic Inspection
2. Y-axis
1) Prepare the following tools and items.
• Harmonic grease 4B No.2
• Waste cloth (rag)
• Phillips-head screwdriver
• Hex wrench set
• Screw Lock (thread sealant)
• Torque-limiting wrench
• Replacement parts (See table below.)
Replacement parts
Parts name
Type No .
OMRON Parts No.
Note
Harmonic drive
SHF-25-80
KN4-M2110-001
S90(JIS)
KN4-M2143-000 Lower part of harmonic drive
O-ring
Rubber wire diameter 1.78mm x Ring inner diameter 69.57mm KN5-M2143-000
For motor
Rubber wire diameter 1.30mm x Ring inner diameter 66.50mm KN5-M257L-000 Supplied with harmonic drive
2) Turn off the controller.
3) Place a sign indicating that the robot is being inspected, to keep others from
operating the controller switch.
4) Enter the safeguard enclosure.
5) Remove the Y-axis arm upper cover. Place the cover on the robot base
(pedestal) side with the machine harness still connected.
Refer to “7 Removing the Robot Covers” in Chapter 4 for removing the
covers.
6) Disconnect the connectors on the Y-axis motor power cable YM and
resolver cable YP.
7) Remove the Y-axis motor installation bolts (M6×20L, 4 pieces) and then
remove the Y-axis motor by swaying it gently right and left.(See Fig. 5-41.)
M6
×
20
Spacer
Fig. 5-41
Summary of Contents for SCARA R6Y-XC Series
Page 2: ......
Page 10: ......
Page 12: ......
Page 29: ...CHAPTER 2 Functions 1 Robot Manipulator 2 1 2 Robot Controller 2 5...
Page 30: ......
Page 36: ......
Page 38: ......
Page 51: ...3 13 CHAPTER 3 Installation Fig 3 7 Ground terminal M4 Ground terminal Ground symbol...
Page 104: ......
Page 128: ......
Page 190: ......
Page 192: ......