YRC ser
ies
2-5
2
1.3.2 PB connector
The PB has an emergency stop button and an enable switch. The contact outputs of these can be used to connect to the
emergency stop circuit of the entire equipment via the SAFETY connector on the controller. This section describes
signal connections.
CAUTION
• Do not change or modify the cable and connector. Along with the input/output signals for the programming box, the PB connector
includes signals used to configure an external safety circuit, and so changing or modifying the cable and connector is very dangerous.
• Always configure an external safety circuit by using the SAFETY connector. Although the PB has an emergency stop button and an
enable switch, they do not function independently because the controller is designed on the assumption that an external safety circuit
is configured.
■
YRC robot controller
Each pin of the PB connector on the PB is connected to each pin of the SAFETY connector and PB SEL connector.
Pin to pin connections are as follows:
PB
PB connector
pin No.
Connected connector
Connector
pin No.
Name
Emergency stop contact:
Line 1
13
Connected to
SAFETY connector
3
E-STOPIN1
14
4
E-STOPIN2
Emergency stop contact:
Line 2
15
5
E-STOPIN3
16
6
E-STOPIN4
Enable contact: Line 1
17
7
LCKIN1
18
8
LCKIN2
Enable contact: Line 2
19
9
LCKIN3
20
10
LCKIN4
Selector switch
21
Connected to
PB SEL connector
−
KEY1
22
−
KEY2
Circuit diagram
Emergency stop
Enable
17
18
19
20
13
14
15
16
3
PB
PB
4
5
6
7
8
9
10
1 to 12
21
22
PB SEL
YRC
Selector
SAFETY