Chapter 3
3-16
System Design and Installation
■
Terminal Block Wire Sizes
●
100-V AC Input (R7D-AP
@
L)
Note 1. Use the same wire sizes for
1,
2, B1, and B2.
Note 2. Connect an OMRON Servomotor Cable to the Servomotor connection terminals.
Item
Model
Unit
R7D-APA3L R7D-APA5L R7D-AP01L R7D-AP02L R7D-AP04L
Power supply capacity
kVA
0.2
0.25
0.4
0.75
1.2
Main circuit
power supply
input (L1, L2)
(See note 1.)
Effective
current
A (rms)
1.64
2.2
4.0
6.8
11
Wire size
mm
2
1.25
1.25
1.25
2
2
Control circuit
power supply
input (L1C,
L2C)
Effective
current
A (rms)
0.13
0.13
0.13
0.13
0.13
Wire size
mm
2
1.25
1.25
1.25
1.25
1.25
Effective
current
A (rms)
0.42
0.6
0.89
2.0
2.6
Wire size
mm
2
1.25
1.25
1.25
1.25
1.25
Wire size
mm
2
2
2
2
2
2
Screw
size
–
M4
M4
M4
M4
M4
Torque
N
⋅
m
1.2
1.2
1.2
1.2
1.2
No-fuse breaker or fuse
capacity
A (rms)
8
8
8
10
13
Servomotor
connection ter-
minal (U, V, W,
)
(See note 2.)
Frame ground
( )
+
+
Summary of Contents for SMARTSTEP A Series
Page 4: ......
Page 6: ......
Page 12: ......
Page 16: ......
Page 18: ......
Page 232: ......
Page 233: ...Chapter 6 Appendix 6 1 Connection Examples ...
Page 248: ......
Page 250: ...R 2 Revision History ...