Chapter 3
3-31
System Design and Installation
Servo Driver inrush current:
With low-speed no-fuse breakers, an inrush current 10 times the rated current flows for 0.02 sec-
onds. For a simultaneous inrush for multiple Servo Drivers, select a no-fuse-breaker with a 20-ms
allowable current greater than the total inrush current shown in the following table for the applicable
Servomotor models.
●
Surge Absorbers
Use surge absorbers to absorb surges from power supply input lines due to lightning, abnormal volt-
ages, etc. When selecting surge absorbers, take into account the varistor voltage, the amount of
surge immunity, and the amount of energy resistance. The surge absorbers shown in the following
table are recommended.
Note 1. Refer to the manufacturers’ documentation for operating details.
Note 2. The surge immunity is for a standard impulse current of 8/20
µ
s. If pulses are wide, either
decrease the current or change to a larger-capacity surge absorber.
●
Noise Filters for Power Supply Input
Use the appropriate noise filter from among those in the following table for the Servo Driver power
supply.
Note The last 2 digits in the noise filter’s model number indicate the type of connection terminals
used. “07” indicates lead-wire terminals. There are also models with soldered faston terminals
(“06”) and screw terminals (“08”). Use the appropriate noise filter for the application. For
details, contact the manufacturer.
Servo Driver
Inrush current (A0-p)
Control-circuit power supply
Main-circuit power supply
R7D-APA3L to -AP02L
30
90
R7D-AP04L
30
90
R7D-APA3H to -AP04H
60
90
R7D-AP08H
60
130
Maker
Model
Max. limit
voltage
Surge
immunity
Type
Remarks
Okaya Electric Indus-
tries Co., Ltd.
R·A·V-781BYZ-2
783 V
1,000 A
Block
For power supply
line
R·A·V-781BXZ-4
78 V
1,000 A
For power supply
line ground
Servo Driver
Noise filter for power supply input
Model
Rated
current
Rated
voltage
Leakage current*
Manufacturer
R7D-APA3L to -AP01L
FN2070-10/07
10 A
250 V
0.4 mA/phase
Schaffner
R7D-AP02L to -AP04L
FN2070-16/07
16 A
R7D-APA3H to -AP02H
FN2070-6/07
6 A
250 V
0.4 mA/phase
Schaffner
R7D-AP04H
FN2070-10/07
10 A
R7D-AP08H
Single-phase
FN2070-16/07
16 A
250 V
0.4 mA/phase
Schaffner
Three-phase
FN258L-16/07
16 A
480 V
2.5 mA (at
250 Vrms, 50 Hz)
Summary of Contents for SMARTSTEP A Series
Page 4: ......
Page 6: ......
Page 12: ......
Page 16: ......
Page 18: ......
Page 232: ......
Page 233: ...Chapter 6 Appendix 6 1 Connection Examples ...
Page 248: ......
Page 250: ...R 2 Revision History ...