XW2B-20G

@

Connecting to the SYSMAC CP1H-Y20DT-D

Servo Driver

 

Connector

 

Pin

 

Numbers

 

Shield

Output Terminal Block 

Pulse

 

output 0

 

CW0+

 

CW0

 

 

CCW0+

 

CCW0

 

 

Origin search 0 (CIO 101, bit 02)

 

24-VDC input terminal (+)

 

24-VDC input terminal (

 

 

)

 

COM (101CH)

 

Input Terminal Block

 

Pulse 0 origin input signal (CIO 0, bit 00)

 

COM (101CH)

 

Pulse 0 origin proximity input signal

 

(CIO 0, bit 01)

 

+CW

CW

+CCW

CCW

+ECRST

ECRST

Shell

 

CP1H-Y20DT-D

 

1.6 k

24 VDC

24 VDC

X1

7
8
9

10

 

11
12

 
 

18
14
13

1.3.5

 

15

 

16

 

19

 

17

 

20




 


 
 

14 
11 
10 

 

 

 

12 

 

13 

INP 

ZCOM 

+24VIN 

 

RUN 

 

OGND 

 

ALM 

 

BKIR 

 

FG

 

X1

XB

 

 

 Using Servo Relay Units 

A Servo Relay Unit can be used when connecting to the Controllers listed in the following table. Refer to 

this table to select the Controller Cable. If there is more than one terminal block plate (the nameplate 

with the signal names) provided with the Servo Relay Unit, use the one for SMARTSTEP and wire the 

terminals correctly. 

 

Controller 

Cable connecting to the 

Controller  

Servo Relay Unit 

Cable connecting to the 

Servo Driver 

C200H-NC112 XW2Z-

@@@

J-A4 

C200HW-NC113 
CS1W-NC113 

XW2Z-

@@@

J-A8 

CS1W-NC133 XW2Z-

@@@

J-A12 

CJ1W-NC113 XW2Z-

@@@

J-A16 

CJ1W-NC133 XW2Z-

@@@

J-A20 

3F88M-DRT141 XW2Z-

@@@

J-A25 

XW2B-20J6-1B 
 
 
 
 

C200H-NC211 XW2Z-

@@@

J-A5 

C200HW-NC213/413 
CS1W-NC213/413 

XW2Z-

@@@

J-A9 

CS1W-NC233/433 XW2Z-

@@@

J-A13 

CJ1W-NC213/413 XW2Z-

@@@

J-A17 

CJ1W-NC233/433 XW2Z-

@@@

J-A21 

XW2B-40J6-2B 
 

CQM1-CPU43-V1 
CQM1H-PLB21 

XW2Z-

@@@

J-A3 XW2B-20J6-3B 

 

XW2B-20J6-8A 
 

CJIM-CPU21 
CJIM-CPU22 
CJIM-CPU23 

XW2Z-

@@@

J-A26 

XW2B-40J6-9A 
(for 2-axis connection) 

XW2Z-

@@@

J-B17  

 

 

 

Summary of Contents for SMARTSTEP Junior

Page 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Page 2: ...Servomotors Servo Drivers USER S MANUAL SMARTSTEP Junior MODELS R7M Z Servomotors R7D ZP Servo Drivers Cat No I553 E1 01...

Page 3: ...e Controller This document describes the Unit models and provides cable specifications and wiring examples SMARTSTEP Junior General purpose Cable Controller Terminal Block Conversion Unit Be sure to c...

Page 4: ...Gray Black ZCOM 6 Blue Red RUN 7 Blue Black 0GND 13 Pink Red BKIR 14 Pink Black INP 12 Green Red ALM Shell Shield FG Terminal block Connector Servo Driver Connector at Terminal Block Conversion Unit C...

Page 5: ...s Controller Connecting to the SYSMAC CP1H X20DT D XW2B 20G Shield Servo Driver Connector Pin Numbers Output Terminal Block Symbol Pulse output 0 CW0 Pulse output 0 CCW0 Origin search 0 101 00 to 03 C...

Page 6: ...ers listed in the following table Refer to this table to select the Controller Cable If there is more than one terminal block plate the nameplate with the signal names provided with the Servo Relay Un...

Page 7: ...rstand its contents before attempting to operate the product Please keep this manual handy for future reference after reading it Be sure that this manual accompanies the product to its final user OMRO...

Page 8: ...2...

Page 9: ...ETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FO...

Page 10: ...t the uses listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this manual Nuclear ene...

Page 11: ...irm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown PERFORMANCE D...

Page 12: ...lease keep this manual close at hand for future reference The following conventions are used to indicate and classify precautions in this manual Always heed the information provided with them Failure...

Page 13: ...by authorized personnel Not doing so may result in electric shock or injury Wiring or inspection must not be performed for at least five minutes after turning OFF the power supply Doing so may result...

Page 14: ...ocations subject to corrosive or flammable gases Locations subject to dust especially iron dust or salts Locations subject to shock or vibration Locations subject to exposure to water oil or chemicals...

Page 15: ...alfunction Use crimp terminals for wiring Do not connect bare stranded wires directly to terminals Connection of bare stranded wires may result in burning Always use the power supply voltage specified...

Page 16: ...ne Not doing so may cause injury When an alarm occurs remove the cause reset the alarm after confirming safety and then resume operation Not doing so may result in injury Do not use the built in brake...

Page 17: ...nings Warning Labels Warning labels are pasted on the product as shown in the following illustration Be sure to follow the instructions given there Warning label Example from R7D ZP01H Warning Label C...

Page 18: ...ervo Driver is damaged or some other fault exists please contact the point of purchase or your OMRON representative Interpreting the Model Number The model number provides information such as the Serv...

Page 19: ...13 Section 1 Features and System Configuration Section 2 Standard Models and Dimensions Section 3 Specifications Section 4 System Design Section 5 Operation Section 6 Troubleshooting Appendix...

Page 20: ...train Input Servo Driver 1 6 1 5 Applicable Standards 1 7 1 5 1 EC Directives 1 7 1 5 2 UL and cUL Standards 1 7 Section 2 Standard Models and Dimensions 2 1 Standard Models 2 2 2 1 1 Servo Drivers 2...

Page 21: ...tion Resistance Unit 3 24 3 5 1 Regeneration Resistance Unit R88A RG08UA Specifications 3 24 3 6 AC Reactors 3 26 3 6 1 AC Reactor Specifications 3 26 Section 4 System Design 4 1 Installation Conditio...

Page 22: ...Precautions When Troubleshooting 6 3 6 1 3 Replacing the Servomotor and Servo Driver 6 3 6 2 Alarm Table 6 4 6 2 1 Alarm Table 6 4 6 3 Troubleshooting 6 5 6 3 1 Error Diagnosis using the Alarm Indica...

Page 23: ...Section 1 Configuration Features and System...

Page 24: ...control 1 1 2 SMARTSTEP Junior Features The SMARTSTEP Junior has the following features No Setup Parameters No parameter settings are required for setup so you can start using the Servo Driver immedia...

Page 25: ...trol Unit with pulse string output SYSMAC PLC with pulse output functions Flexible Motion Controller with pulse I O SYSMAC CJ1 CS1 C series Programmable Controller SMARTSTEP Junior Servo Driver R7D ZP...

Page 26: ...vomotor power Power supply indicator PWR Rotary switch for setting command filter FIL Control I O connector CN1 Rotary Switch for Setting Command Pulse PULSE Always turn OFF the power supply before se...

Reviews: