background image

Safety 

Technology 

& Innovation 

 

• 

Earth fault monitoring 

• 

Indication of the switching state via LED 

• 

Up to PL e, SILCL 3, category 4 

• 

It is not allowed to open the device, tamper with the de-

vice or bypass the safety devices. 

• 

All relevant safety regulations and standards are to be 

observed. 

• 

The overall concept of the control system in which the 

device is incorporated must be validated by the user. 

• 

Failure to observe the safety regulations can result in 

death, serious injury and serious damage. 

Correct Use 

The SR105E contact block in combination with any basic device 

from  the  OMRON  STI  SR  series  can  be  used  to  produce  up  to 

three  additional  safety  contact  paths  per  device.  An  existing 

system can thus be expanded practically indefinitely in a modu-

lar  manner.  Activation  takes  place  via  a  safety  contact  of  the 

basic  device.  The  SR105E  provides  signaling  contacts  for  fault 

monitoring.  The  devices  can  be  used  in  systems  up  to  safety 

category 4, PL e. 

Features 

• 

3 safe, redundant relay outputs 

1 auxiliary contact (fault monitoring) 

• 

Activation via basic device from the OMRON STI SR 

series 

• 

Modular, freely configurable safety system 

• 

Fault monitoring by basic device 

Function 

The safety expansion contact block SR105E in combination 

with  a  basic  device  from  the  OMRON  STI  SR  series  is 

designed  for  safe  isolation  of  safety  circuits  according  to 

EN 60204-1 and can be used up to safety category 4, PL e 

according to EN ISO 13849-1. 
Terminal  S11  (DC  24V  control  voltage)  is  connected  with 

terminals S15 and S16 via the safety contacts of the basic 

device.  Starting  the  basic  device  also  activates  the 

SR105E. The basic device disconnects the control voltage 

when the safety switch is operated, and the safety contacts 

of the SR105E open immediately. 
If a fault occurs in the SR105E, this is detected by the basic 

device via terminals S23 and S24. 
Independent  operation  without  basic  device  is  not 

possible . 

Electrical  

Connection 

• 

When the 24 V version is used, a control transformer 

according to EN 61558-2-6 or a power supply unit with 

electrical isolation from the mains must be connected. 

• 

External fusing of the safety contacts (4 A slow-blow or 6 

A quick-action or 10 A gG) must be provided. 

• 

A maximum length of the control lines of 1000 meters 

with a line cross section of 0.75 mm

2

 must not be ex-

ceeded. 

• 

The line cross section must not exceed 2.5 mm

2

• 

If the device does not function after commissioning, it 

must be returned to the manufacturer unopened. Open-

ing the device will void the warranty. 

• 

PE (protective earth) must be connected to terminal S10 

on the AC 115/230V variant. Wiring of the overall device 

is to be designed for 115/230V. 

Installation 

As per EN 60204-1, the device is intended for installation in 

control  cabinets  with  a  minimum  degree  of  protection  of 

IP54. It is mounted on a 35-mm DIN rail according to DIN 

EN 60715 TH35. 

Safety  

Precautions 

• 

Installation and commissioning of the device must be 

performed only by authorized personnel . 

• 

Observe the country-specific regulations when installing 

the device. 

• 

The electrical connection of the device is only allowed to 

be made with the device isolated. 

• 

The wiring of the device must comply with the instruc-

tions in this user information, otherwise there is a risk 

that the safety function will be lost. 

Fig. 1 Block diagram SR105E 

Fig. 2  Installation / removal 

Fig. 3  Connections 

A1:  

Power supply 

A2 : 

Power supply 

S11:  

DC 24V control voltage 

S10:  

control line  

S15: 

control line  

S16: 

control line  

S23: 

Fault monitoring 

S24:    

Fault monitoring 

13-14: 

Safety contact 1 

23-24: 

Safety contact 2 

33-34: 

Safety contact 3 

(not for the plug-in terminals) 

SR105E 

User Information for SR105E  

Summary of Contents for SR105E

Page 1: ... of the SR105E open immediately If a fault occurs in the SR105E this is detected by the basic device via terminals S23 and S24 Independent operation without basic device is not possible Electrical Connection When the 24 V version is used a control transformer according to EN 61558 2 6 or a power supply unit with electrical isolation from the mains must be connected External fusing of the safety co...

Page 2: ...ction IP54 the fault involving a short circuit between the activation lines can be ruled out protected wiring space Category 4 PL e according to EN ISO 13849 1 is thereby possible If this fault cannot be ruled out category 3 PL e is achieved Applications Fig 3 Feedback loop Contactors connected to the SR105E or the basic devices are monitored via the feedback loop of the basic device KA and KB are...

Page 3: ... C 0 6 o t C 5 1 V 4 2 C D e g n a r e r u t a r e p m e T C 0 4 o t C 5 1 V 5 1 1 0 3 2 C A 1 0 1 1 0 E D V N I D 2 n o i t a n i m a t n o c f o e e r g e D 1 0 1 1 0 E D V N I D 3 y r o g e t a c e g a t l o v r e v O g 0 3 2 x o r p p a t h g i e W 5 3 H T 5 1 7 0 6 N E o t g n i d r o c c a l i a r N I D g n i t n u o M Note Additional data can be requested from the manufacturer for applicati...

Page 4: ... applied OMRON Scientific Technologies Inc 6550 Dumbarton Circle Fremont CA 94555 U S A Directives applied EMC directive 2004 108 EC Machinery directive 2006 42 EC Standards applied EN ISO 13849 1 2008 AC 2009 EN 62061 2005 Fremont May 2014 Marty Krikorian Director Quality Control The signed EC Declaration of Conformity is included with the product RoHS directive 2002 95 EC Authorized Signer of De...

Page 5: ...stems Machine Automation Controllers MAC Programmable Controllers PLC Operator interfaces HMI Distributed I O Software Drives Motion Controls Servo AC Drives Motion Controllers Encoders Temperature Process Controllers Single and Multi loop Controllers Sensors Vision Proximity Sensors Photoelectric Sensors Fiber Optic Sensors Amplified Photomicrosensors Measurement Sensors Ultrasonic Sensors Vision...

Reviews: