No.19S182-01
47/73
STC-MBA503POE / STC-MCA503POE
Product Specifications and User’s Guide
10.8
Gamma correction
The gamma correction is changeable.
GenICam Parameters
Gamma
IFloat Type
Gamma correction
Range: 0 to 4.0
Default: 1.0
10.9
ROI (Region of Interest)
The specified region of image can be output from camera with ROI function.
GenICam Paramters
Width
IInteger Type
Width (horizontal size) of output image (in pixel)
Range: 8 to 2,592
Default: 2,592
Adjustable steps: 8
(“Width” + “Offset X”) should not exceeded maximum width.
Height
IInteger Type
Height (vertical size) of output image (in line)
Range: 2 to 1,944
Default: 1,944
Adjustable steps: 2
(“Height” + “Offset Y”) should not exceeded maximum height.
OffsetX
IInteger Type
Horizontal offset for output image (in pixel)
Range: 0 to 2,584
Default: 0
Adjustable steps: 8
OffsetY
IInteger Type
Vertical offset for output image (in line)
Range: 0 to 1,942
Default: 0
Adjustable steps: 2
The ROI region settings are below:
Width
Height
OffsetX
OffsetY
ROI region