118
Main Setup [200]
Section 11-2
Communication information
Brake Fault [25V]
Select the preferred way to react to an alarm trip, activate auto reset and
specify delay time.
Communication information
11-2-8 Serial Communication [260]
This function is to define the communication parameters for serial communi-
cation. There are two types of options available for serial communication,
RS232/485 (Modbus/RTU) and fieldbus modules (Profibus, DeviceNet and
Ethernet). For more information see chapter Serial communication and
respective option manual.
Comm Type [261]
Select RS232/485 [262] or Fieldbus [263].
Note
Toggling the setting in this menu will perform a soft reset (re-boot) of the
Fieldbus module.
Modbus Instance no/
DeviceNet no:
43100
Profibus slot/index
169/4
EtherCAT index (hex)
4c1c
Fieldbus format
UInt
Modbus format
UInt
Default
Off
Off
0
Autoreset not activated.
1 - 3600s
1 -
3600
s
Brake fault auto reset delay time.
Modbus Instance no/
DeviceNet no:
43070
Profibus slot/index
169/229
EtherCAT index (hex)
4bfe
Fieldbus format
Long, 1=1s
Modbus format
EInt
25V Brk
Fault
Stp Off
A
Default:
RS232/485
RS232/485
0
RS232/485 selected
Fieldbus
1
Fieldbus selected (Profibus, DeviceNet or Modbus/TCP)
261 Com Type
Stp
RS232/485
A
Summary of Contents for SX-F
Page 2: ......
Page 14: ...6 Table of contents...
Page 20: ...12 Glossary Section 1 6...
Page 32: ...24 Cabinet mounting Section 2 3...
Page 58: ...50 Connecting options Section 5 6...
Page 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Page 74: ...66 EMC standards Section 8 1...
Page 266: ...258 System Data 900 Section 11 9...
Page 274: ...266 Maintenance Section 12 3...
Page 284: ...276 Liquid cooling Section 13 12...