179
Load Monitor and Process Protection [400]
Section 11-4
Fig. 92
Communication information
Max Alarm [416]
Max Alarm Margin [4161]
With load type Basic, [415], used the Max Alarm Margin sets the band above
the Normal Load, [41B], menu that does not generate an alarm. With load
type Load Curve, [415], used the Max Alarm Margin sets the band above the
Load Curve, [41C], that does not generate an alarm. The Max Alarm Margin is
a percentage of nominal motor torque.
Communication information
Default:
Basic
Basic
0
Uses a fixed maximum and minimum load level over the full
speed range. Can be used in situations where the torque is
independent of the speed.
Load Curve
1
Uses the measured actual load characteristic of the pro-
cess over the speed range.
Modbus Instance no/
DeviceNet no:
43325
Profibus slot/index
169/229
EtherCAT index (hex)
4cfd
Fieldbus format
UInt
Modbus format
UInt
Default:
15%
Range:
0–400%
Modbus Instance no/
DeviceNet no:
43326
Profibus slot/index
169/230
EtherCAT index (hex)
4cfe
Fieldbus format
Long, 1=1%
Modbus format
EInt
Basic
Load curve
Load
Speed
Max Alarm
Min Alarm
Basic
A
15%
A
Summary of Contents for SX-F
Page 2: ......
Page 14: ...6 Table of contents...
Page 20: ...12 Glossary Section 1 6...
Page 32: ...24 Cabinet mounting Section 2 3...
Page 58: ...50 Connecting options Section 5 6...
Page 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Page 74: ...66 EMC standards Section 8 1...
Page 266: ...258 System Data 900 Section 11 9...
Page 274: ...266 Maintenance Section 12 3...
Page 284: ...276 Liquid cooling Section 13 12...