202
I/Os and Virtual Connections [500]
Section 11-5
Note
When selections AnIn1, AnIn2 …. AnIn4 is selected, the setup of the AnOut
(menu [532] or [535]) has to be set to 0-10V or 0-20mA. When the AnOut
Setup is set to e.g. 4-20mA, the mirroring is not working correct.
Communication information
Preset scaling and offset of the output configuration.
Communication information
Speed Ref
14
Actual internal speed reference Value after ramp and V/Hz.
Torque Ref
15
Actual torque reference value
(=0 in V/Hz mode)
Modbus Instance no/
DeviceNet no:
43251
Profibus slot/index
169/155
EtherCAT index (hex)
4cb3
Fieldbus format
UInt
Modbus format
UInt
Default:
4-20mA
4–20mA
0
The current output has a fixed threshold (Live Zero) of 4
mA and controls the full range for the output signal. See
Fig. 97.
0–20mA
1
Normal full current scale configuration of the output that
controls the full range for the output signal. See Fig. 96.
User mA
2
The scale of the current controlled output that controls the
full range for the output signal. Can be defined by the
advanced AnOut Min and AnOut Max menus.
User Bipol mA
3
Sets the output for a bipolar current output, where the scale
controls the range for the output signal. Scale can be
defined in advanced menu AnOut Bipol.
0-10V
4
Normal full voltage scale configuration of the output that
controls the full range for the output signal. See Fig. 96.
2–10V
5
The voltage output has a fixed threshold (Live Zero) of 2 V
and controls the full range for the output signal. See Fig.
97.
User V
6
The scale of the voltage controlled output that controls the
full range for the output signal. Can be defined by the
advanced AnOut Min and AnOut Max menus.
User Bipol V
7
Sets the output for a bipolar voltage output, where the scale
controls the range for the output signal. Scale can be
defined in advanced menu AnOut Bipol.
Modbus Instance no/
DeviceNet no:
43252
Profibus slot/index
169/156
EtherCAT index (hex)
4cb4
Fieldbus format
UInt
Modbus format
UInt
4-20mA
A
Summary of Contents for SX-F
Page 2: ......
Page 14: ...6 Table of contents...
Page 20: ...12 Glossary Section 1 6...
Page 32: ...24 Cabinet mounting Section 2 3...
Page 58: ...50 Connecting options Section 5 6...
Page 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Page 74: ...66 EMC standards Section 8 1...
Page 266: ...258 System Data 900 Section 11 9...
Page 274: ...266 Maintenance Section 12 3...
Page 284: ...276 Liquid cooling Section 13 12...