225
Logical Functions and Timers [600]
Section 11-6
Analog comparator 3, Value [6131]
Function is identical to analogue comparator 1 value [6111].
Communication information
Analogue Comparator 3 Level High [6132]
Function is identical to analogue comparator 1 level high [6112].
Communication information
Analogue Comparator 3 Level Low [6133]
Function is identical to analogue comparator 1 level low [6113].
Communication information
Default:
Process Value
Selections:
Same as in menu [6111]
Modbus Instance no/
DeviceNet no:
43471
Profibus slot/index
170/120
EtherCAT index (hex)
4d8f
Fieldbus format
UInt
Modbus format
UInt
Default:
300rpm
Range:
Enter a value for the high level.
Modbus Instance no/
DeviceNet no:
43472
Profibus slot/index
170/121
EtherCAT index (hex)
4d90
Fieldbus format
Long
1=1 W, 0.1 A, 0.1 V,
0.1 Hz, 0.1
C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process
value
Modbus format
EInt
Default:
200rpm
Range:
Enter a value for the low level.
Modbus Instance no/
DeviceNet no:
43473
Profibus slot/index
170/122
EtherCAT index (hex)
4d91
Fieldbus format
Long,
1=1 W, 0.1 A, 0.1 V,
0.1 Hz, 0.1
C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process
value
Modbus format
EInt
6131 CA3 Value
Stp
Process Val
A
6132 CA3 Level HI
Stp
300rpm
A
6133 CA3 Level LO
Stp
200rpm
A
Summary of Contents for SX-F
Page 2: ......
Page 14: ...6 Table of contents...
Page 20: ...12 Glossary Section 1 6...
Page 32: ...24 Cabinet mounting Section 2 3...
Page 58: ...50 Connecting options Section 5 6...
Page 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Page 74: ...66 EMC standards Section 8 1...
Page 266: ...258 System Data 900 Section 11 9...
Page 274: ...266 Maintenance Section 12 3...
Page 284: ...276 Liquid cooling Section 13 12...