72
The control panel
Section 9-2
Remote mode
When the VSD is switched to REMOTE operation, the VSD will be controlled
according to selected control methods in the menu’s Reference Control [214],
Run/Stop Control [215] and Reset Control [216].
To monitor the actual Local or Remote status of the VSD control, a “Loc/Rem”
function is available on the Digital Outputs or Relays. When the VSD is set to
Local, the signal on the DigOut or Relay will be active high, in Remote the sig-
nal will be inactive low. See menu Digital Outputs [540] and Relays [550].
9-2-6
Function keys
The function keys operate the menus and are also used for programming and
read-outs of all the menu settings.
Fig. 58 Menu structure
Table 22 Function keys
ENTER key:
-Step to a lower menu level
-Confirm a changed setting
ESCAPE key:
-Step to a higher menu level
-Ignore a changed setting, without confirming
PREVIOUS key:
-Step to a previous menu within the same level
-Go to more significant digit in edit mode
NEXT key:
-Step to a next menu within the same level
-Go to less significant digit in edit mode
- key:
-Decrease a value
-Change a selection
+ key:
-Increase a value
-Change a selection
Summary of Contents for SX-F
Page 2: ......
Page 14: ...6 Table of contents...
Page 20: ...12 Glossary Section 1 6...
Page 32: ...24 Cabinet mounting Section 2 3...
Page 58: ...50 Connecting options Section 5 6...
Page 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Page 74: ...66 EMC standards Section 8 1...
Page 266: ...258 System Data 900 Section 11 9...
Page 274: ...266 Maintenance Section 12 3...
Page 284: ...276 Liquid cooling Section 13 12...