SECTION 11
Functional Description
This chapter describes the menus and parameters in the software. You will
find a short description of each function and information about default values,
ranges, etc. There are also tables containing communication information. You
will find the Modbus, DeviceNet, EtherCAT and Fieldbus address for each
parameter as well as the enumeration for the data.
Note
Functions marked with the sign
cannot be changed during Run Mode.
Description of table layout
Resolution of settings
The resolution for all range settings described in this chapter is 3 significant
digits. Exceptions are speed values which are presented with 4 significant dig-
its. Table 23 shows the resolutions for 3 significant digits.
11-1 Preferred View [100]
This menu is displayed at every power-up. During operation, the menu [100]
will automatically be displayed when the keyboard is not operated for 5 min-
utes. The automatic return function will be switched off when the Toggle and
Stop key is pressed simultaneously. As default it displays the reference and
torque values.
Menu [100], Preferred View displays the settings made in menu [110], 1st line,
and [120], 2nd line. See Fig. 62.
Fig. 62
Display functions
Default:
Selection or
range
Integer value of
selection
Description
Table 23
3 Digit
Resolution
0.01-9.99
0.01
10.0-99.9
0.1
100-999
1
1000-9990
10
10000-99900
100
Menu no.
Menu
name
0rpm
Stp 0.0Nm
A
Line)
Stp (2nd
Line)
A
Summary of Contents for SX-F
Page 2: ......
Page 14: ...6 Table of contents...
Page 20: ...12 Glossary Section 1 6...
Page 32: ...24 Cabinet mounting Section 2 3...
Page 58: ...50 Connecting options Section 5 6...
Page 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Page 74: ...66 EMC standards Section 8 1...
Page 266: ...258 System Data 900 Section 11 9...
Page 274: ...266 Maintenance Section 12 3...
Page 284: ...276 Liquid cooling Section 13 12...