97
Main Setup [200]
Section 11-2
Only visible if the Encoder option board is installed. This parameter describes
the number of pulses per rotation for your encoder, i.e. it is encoder specific.
For more information please see the encoder manual.
Communication information
Only visible if the Encoder option board is installed. This parameter shows the
measured motor speed. To check if the encoder is correctly installed, set
Encoder feedback [22B] to Off, run the VSD at any speed and compare with
the value in this menu. The value in this menu [22D] should be about the
same as the motor speed [712]. If you get the wrong sign for the value, swap
encoder input A and B.
Communication information
.
Encoder Pulse counter [22F]
Only visible if the encoder option is installed. Adde menu/parameter for accu-
mulated QEP (Quadrature Encoder Pulse) encoder pulses. Can be preset to
any value within format used (Int = 2 byte, Long = 4 byte)
.
Default:
1024
Range:
5–16384
Modbus Instance no/
DeviceNet no:
43052
Profibus slot/index
168/211
EtherCAT index (hex)
4bec
Fieldbus format
Long, 1=1 pulse
Modbus format
EInt
Unit:
rpm
Resolution:
speed measured via the encoder
Modbus Instance no/
DeviceNet no:
42911
Profibus slot/index
168/70
EtherCAT index (hex)
4b5f
Fieldbus format
Int
Modbus format
Int
Default:
0
Resolution
1
22C Enc Pulses
Stp M1:
1024
A
M1:
XXrpm
A
22F Enc Puls Ctr
Stp
0
A
Summary of Contents for SX-F
Page 2: ......
Page 14: ...6 Table of contents...
Page 20: ...12 Glossary Section 1 6...
Page 32: ...24 Cabinet mounting Section 2 3...
Page 58: ...50 Connecting options Section 5 6...
Page 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Page 74: ...66 EMC standards Section 8 1...
Page 266: ...258 System Data 900 Section 11 9...
Page 274: ...266 Maintenance Section 12 3...
Page 284: ...276 Liquid cooling Section 13 12...