103
Main Setup [200]
Section 11-2
the run.
If the sets are using different motors (M1 to M4) the set will be
changed only when the motor is stopped.
Communication information
The active set can be viewed with function [721] VSD status.
Note
Parameter set cannot be changed during run if the parameter set includes
change of the motor set (M2-M4).
Prepare parameter Set when different Motor data M1-M4:
1.
Select desired parameter Set to be set in [241] A-D.
2.
Select Motor Set [212] if other than the default Set M1.
3.
Set relevant motor data in the Menu group [220].
4.
Set other desired parameter settings to belong to this parameter Set.
To prepare a Set for another motor, repeat these steps.
Copy Set [242]
This function copies the content of a parameter set into another parameter
set.
Default:
A
Selection:
A, B, C, D, DigIn, Com, Option
A
0
Fixed selection of one of the 4 parameter sets A, B, C or D.
B
1
C
2
D
3
DigIn
4
Parameter set is selected via a digital input. Define which
digital input in menu [520], Digital inputs.
Com
5
Parameter set is selected via serial communication.
Option
6
The parameter set is set via an option. Only available if the
option can control the selection.
Modbus Instance no/
DeviceNet no:
43022
Profibus slot/index
168/181
EtherCAT index (hex)
4bce
Fieldbus format
UInt
Modbus format
UInt
241 Select Set
Stp
A
A
Default:
A>B
A>B
0
Copy set A to set B
A>C
1
Copy set A to set C
242 Copy Set
Stp
A
>
B
A
Summary of Contents for SX-F
Page 2: ......
Page 14: ...6 Table of contents...
Page 20: ...12 Glossary Section 1 6...
Page 32: ...24 Cabinet mounting Section 2 3...
Page 58: ...50 Connecting options Section 5 6...
Page 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Page 74: ...66 EMC standards Section 8 1...
Page 266: ...258 System Data 900 Section 11 9...
Page 274: ...266 Maintenance Section 12 3...
Page 284: ...276 Liquid cooling Section 13 12...