59
Remote control functions
Section 7-2
Fig. 45 Example of wiring for Run/Stop/Enable/Reset inputs
The Enable input must be continuously active in order to accept any run-right
or run-left command. If both RunR and RunL inputs are active, then the VSD
stops according to the selected Stop Mode. Fig. 46 gives an example of a
possible sequence.
Fig. 46 Input and output status for level-control
Run Inputs Edge-controlled
Menu [21A] Start signal Level/Edge must be set to Edge to activate edge con-
trol. This means that an input is activated by a “low” to “high” transition or vice
versa.
Note
Edge-controlled inputs comply with the Machine Directive (see chapter EMC),
if the inputs are directly used for starting and stopping the machine.
X1
1
12
22
11
2
3
4
5
6
7
8
9
10
13
14
15
16
17
18
19
20
21
Stop
Reset
+24 V
RunL
RunR
Enable
(06-F103new_1)
INPUTS
OUTPUT
STATUS
ENABLE
STOP
RUN R
RUN L
Right rotation
Left rotation
Standstill
Summary of Contents for SX-F
Page 2: ......
Page 14: ...6 Table of contents...
Page 20: ...12 Glossary Section 1 6...
Page 32: ...24 Cabinet mounting Section 2 3...
Page 58: ...50 Connecting options Section 5 6...
Page 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Page 74: ...66 EMC standards Section 8 1...
Page 266: ...258 System Data 900 Section 11 9...
Page 274: ...266 Maintenance Section 12 3...
Page 284: ...276 Liquid cooling Section 13 12...