7-48
Message
The label (name) of the response. Input an appropriate, easy-to-distinguish name.
Note
Set the label in the Recv message box in the table shown under
Creating a Step
.
Header <h>
Terminator <t>
Set the header and terminator.
Note
No header or terminator is used for communications with the 3G3JV. Therefore, set both to
None
.
Check Code <c>
Set the check code.
Note
The CRC-16 check code is used for communications with the 3G3JV. Select the CRC-16 check
code and set the initial value to 65535.
Select
Reverse
for the conversion method. Then select
BIN
as the data type.
Length <l>
Set the length of the data.
Note
All communications with the 3G3JV are performed in byte units. Select
1 Byte
and
BIN
. Select
No
for reading data because there is no data to be read.
Address <a>
Set the addresses of the Slaves.
Note
In this example, the Slave addresses are set in S + 2, S + 5, and S + 8. Therefore, retrieve the data
from those locations.
The address is set in the LSB of each word. To read the byte, select
Variable Reverse
, otherwise
the data will be read from the LSB. Then click on
Edit Variable
with the left button of the mouse.
Select
Read R ()
and set
Data/Address
to the operand (3N + 2) using the number (N) of times to
repeat the step.
Set
Edit Length
to 1 byte as a default. If the default value has been changed, set it to 0N + 1.
Data
Set the expected response in details.
•
Response to the RUN Command and Frequency Reference
The response to the DSR message written consists of the following items.
CRC-16 check (Set with <c>)
Number of write data registers: 2
Write start register number (RUN command: 0001)
Function code (Write 10)
Slave address (Set with <a>)
Set data: <a> + [10] + [00] + [01] + [00] + [02] + <c>
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3JV-A4002
Page 1: ...USER S MANUAL SYSDRIVE 3G3JV Compact Simplified Inverters Cat No I528 E1 04...
Page 3: ...USER S MANUAL Compact Simplified Inverter SYSDRIVE 3G3JVSERIES...
Page 16: ......
Page 20: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 26: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 57: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 65: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 216: ...Chapter 10 List of Parameters 10...
Page 229: ...Chapter 11 Using the Inverter for a Motor 11...