Inverter model
3G3SV-
-E
B2037
B2022
B2015
B2007
B2004
B2002
3-phase
Inverter model
3G3SV-
-E
BB037
BB022
BB015
BB007
BB004
BB002
Single-phase
Operation
conditions
Input
signals
Operation signal
Forward operation/reverse operation by individual com-
mand
External fault
Output stops by external fault input.
Reset
Releases protection while the function is operating.
Multifunction set-
ting
Possible to set max. 9 speed
Multifunction input
selection
Multifunction contact input: two of the following signals
available to select.
Multispeed command 3, jog operation, accel/decel time
select, 3 wire sequence, external coasting stop, speed
search
Output
signals
Operation state
(photocoupler out-
put)
Multifunction contact output: two of the following signals
available to select.
During running output, zero speed, frequency agree, out-
put frequency
≥
setting value, during overtorque detection
Fault contact
NO/NC contact output
Built-in function
The following set-up is available: frequency reference bias/
gain, upper/lower frequency limit, DC braking stop current
at start, s-curve characteristics, torque boost, frequency
meter calibrating gain, auto reset/restart operation
Monitor
display
f
ti
7 segments, 3-dig-
its display section
Displays output frequency and contents at protective func-
tion operation.
y
function
Digital operator
(optional)
Displays setting frequency, output frequency, output cur-
rent, rotating direction, and the contents at protective func-
tion operation.
Analog output mon-
itor
Analog output (0 to 10 VDC). Possible to select output fre-
quency or output current.
Protective configuration
Open chassis
Cooling method
Self-cooling
Forced cooling
Weight
lb (kg)
4.4 (2)
4.4 (2)
6.6 (3)
6.6 (3)
13 (6)
13 (6)
Environmental
C
diti
Location
Indoor (protected from corrosive gases and dust)
Conditions
Ambient temperature
+14
to 122
F (--10
to +50
C) (not frozen)
Storage temperature
(see note 3)
--4
to 140
F (--20
to +60
C)
Humidity
90% RH (non-condensing)
Vibration
0.6 G
Note
1. Our standard 4-pole motor is used for maximum applicable mo-
tor output.
2. Allowable values for the applications not requiring overload.
3. Temperature during shipping (for short period).
Section 1-8