Function
See
Page
User
set
values
Initial
setting
Description
Name
No.
Software ver-
sion
49
PROM No.
PROM No. is displayed (setting dis-
abled).
---
Frequency
jump control
50
Setting pro-
hibit fre-
quency 1
Setting unit: 0.1 Hz, setting range: 0.0 to
400.0
0.0 Hz
54
51
Setting pro-
hibit fre-
quency 2
Setting unit: 0.1 Hz, setting range: 0.0 to
400.0
0.0 Hz
52
Setting pro-
hibit fre-
quency 2
Setting unit: 0.1 Hz, setting range: 0.0 to
400.0
0.0 Hz
53
Setting pro-
hibit fre-
quency
range
Setting unit: 0.1 Hz, setting range: 0.0 to
25.5
1.0 Hz
Speed search
control
54
Speed
search
deactivation
current level
Setting unit: 1%, setting range: 0 to 200
150%
54
55
Min. base-
block time
Setting unit: 0.1 s, setting range: 0.0 to
5.0
0.5 s
56
V/F during
speed
search
Setting unit: 0.1 s, setting range: 0.0 to
100.0
100%
Note
1. Can be changed even during run.
2. When setting the third function, set
93
to 3.
2-10 Description of Functions and Constants
Constant Nos. are indicated as No. N.
2-10-1 Password Setting
Item name
Constant to be set
Factory preset
First function (0 to 19) selection
No. 0
1
First, second function (0 to 29) selection
No. 0
1
First, second, third function (0 to 49) selection
No. 0
1
The first functions (No. 0 to No. 19) can be set and read.
No. 0 = 1
The first and second functions (No. 0 to No. 29) can be set and
read.
No. 0 = 2
The first, second and third functions (No. 0 to No. 59) can be set
and read.
No. 0 = 3
Section 2-10