63
Program
11006
RESET COUNTER
25315
MOV (21)
#0000
111
11004
(ON for one cycle)
11002
11000
DIFD (14) 03000
03001
11000
03000
03001
Output #4
START
25313 (usually ON)
Counter and outputs reset.
Preset number set (here, to
00). Programming within the
dotted line can be omitted if the
preset number is 00.
ENABLE OUTPUT turned ON.
START
Completion of cutter opera-
tion detected (OFF).
Outputs indicates completion
of cutting.
4-4
Gate, Latch, and Sampling Modes
In gate, latch, and sampling modes counter values are incremented and decre-
mented while the count signal is ON and according to any of the three types of
input pulses. All three modes permit counting between –8,388,608 and
8,388,607. All modes but cumulative gate mode use control input IN1 as the
count (start) signal. The cumulative gate mode uses control input IN1 as the re-
set signal and control input IN2 as the count (start) signal; latch mode uses con-
trol input IN2 as the latch signal. None of these modes support external outputs.
Control inputs can be designated to originate in IR bits.
Gate, Latch, and Sampling Modes
Section 4-4