51
X-Axis Parameters
Description
Unit
Pulse rate
Rotation direction
Encoder type
Gain
In-position zone
Backlash
compensation
Stroke limit (+)
Stroke limit (–)
Zone settings
Home shift
Maximum speed
Maximum jogging speed
Origin search direction
Origin compensation
High origin search speed
Origin search acceleration
and deceleration
Low origin search speed
Deceleration-stop
Address
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
Setting
0
1
0
01
200
10
0
999,999
999,999
01000100
0
10,000
2,000
0
0
5,000
5
1,000
500
Attributes
Pulse
1 unit/pulse
Positive voltage output
with incremental
positioning actions
Single multiplier,
positive logic
2,000
µ
V/pulse
pulses
None
pulses
pulses
Accel. zone 100 pulses
Accel. zone 100 pulses
pulses
pps
pps
Direction of positive
voltage output
pulses
pps
Acceleration time =200ms
Deceleration time =200ms
pps
pulses
Initial Data
Section 3-8