100
NC Unit Error Logs
Section 10-1
Sensor
inputs
Emergency
stop input
6000
The axis was stopped by an emer-
gency stop signal input.
Start operation again
after clearing the
emergency stop input
and executing
RELEASE PROHIBIT/
ERROR RESET.
An emergency stop
will be performed on
the affected axis.
Other operating axes
will not be affected.
CW limit stop
6100
The axis was stopped by a CW
limit input signal.
Move in the CCW
direction after execut-
ing RELEASE PRO-
HIBIT/ERROR RESET.
CCW limit
stop
6101
The axis was stopped by a CCW
limit input signal.
Move in the CW direc-
tion after executing
RELEASE PROHIBIT/
ERROR RESET.
Origin
search
No origin
proximity
input signal
6200
The Unit is set for a proximity input
signal, but no origin proximity
input signal was received during
the origin search.
Perform the origin
search again after
checking the origin
proximity input signal
wiring and the origin
proximity input signal
type (N.C. or N.O.) in
the axis parameters’ I/
O settings. If the signal
type is changed, reset
the power supply or
restart the NC Unit
before resuming oper-
ation.
Other operating axes
will not be affected.
No origin
input signal
6201
There was no origin input signal
received during the origin search.
Perform the origin
search again after
checking the origin
input signal wiring and
the origin input signal
type (N.C. or N.O.) in
the axis parameters’ I/
O settings. If the signal
type is changed, reset
the power supply or
restart the NC Unit
before resuming oper-
ation.
Group
Name
Code
Cause
Clearing method
Operation after error
Summary of Contents for SYSMAC W398-E1-1
Page 1: ...23 5 7 21 0 18 Cat No W398 E1 1 SYSMAC WS02 NCTC1 E CX Position...
Page 2: ......
Page 3: ...WS02 NCTC1 E CX Position Operation Manual Produced July 2001...
Page 4: ...iv...
Page 10: ......
Page 76: ......
Page 80: ......
Page 94: ......
Page 100: ......
Page 104: ......
Page 124: ......
Page 126: ......