13
Connecting to a PC
Section 2-2
2-1-2
Uninstalling CX-Position or FinsGateway
Uninstalling CX-Position
Use the following procedure to remove CX-Position from the computer.
1,2,3...
1.
Click Start on the task bar and move the cursor to Settings.
2.
Select Control Panel.
3.
Double-click the Add/Remove Programs Icon.
4.
The Add/Remove Programs Properties Dialog Box will be displayed. Se-
lect CX-Position from the Install/Uninstall List and click the Add/Remove
Button.
5.
Click OK in the confirmation dialog box. CX-Position will be removed from
the computer.
Uninstalling FinsGateway
Use the following procedure to remove FinsGateway from the computer.
1,2,3...
1.
Click the Start on the task bar and move the cursor to Settings.
2.
Select Control Panel.
3.
Double-click the Add/Remove Programs Icon.
4.
The Add/Remove Programs Properties Dialog Box will be displayed. Se-
lect OMRON FinsG SerialUnit Embedded Edition from the In-
stall/Uninstall List and click the Add/Remove Button.
5.
Click OK in the confirmation dialog box. FinsGateway will be removed from
the computer.
Note Do not attempt to uninstall CX-Position or FinsGateway Version 3 when they
are running. The uninstall operation may not be completed successfully.
2-2
Connecting to a PC
Note If OMRON Support Software that communicates using CX-Server (e.g., CX-
Programmer, CX-Protocol, or CX-Motion) or an application that uses a special
serial driver is connected online, it is not possible to perform online operations
from CX-Position using the same COM port. Quit online connection for the
OMRON Support Software that communicates using CX-Server (e.g., CX-
Programmer, CX-Protocol, or CX-Motion) or the application that uses a spe-
cial serial driver, and then re-attempt online operations from CX-Position after
starting up FinsGateway’s Serial Unit servicing.
CX-Position can be connected to the PC using any of the following methods.
Note Connection is also possible to PCs on Controller Link, SYSMAC LINK, or
Ethernet networks via Host Link (using the PC’s gateway functions).
Any FinsGateway Version 2 driver can be used.
FinsGateway Version 3 Embedded Edition is included with CX-Position. The
following explanation is for when FinsGateway Version 3 Embedded Edition is
used.
Use the following procedure to start up the FinsGateway communications
driver. For details, refer to 6-2 FinsGateway Configuration and Startup.
Network type
Computer port
FinsGateway
communications driver
Host Link (SYSWAY-
CV)
(See note.)
RS-232C port
Serial Unit driver
Ethernet
Ethernet port (or built-in port)
Ethernet driver
Summary of Contents for SYSMAC W398-E1-1
Page 1: ...23 5 7 21 0 18 Cat No W398 E1 1 SYSMAC WS02 NCTC1 E CX Position...
Page 2: ......
Page 3: ...WS02 NCTC1 E CX Position Operation Manual Produced July 2001...
Page 4: ...iv...
Page 10: ......
Page 76: ......
Page 80: ......
Page 94: ......
Page 100: ......
Page 104: ......
Page 124: ......
Page 126: ......