4.1.2 Boundary setting
Set the working area boundary for the robot.
B Start:
Work start point
B End:
Work end point
Range:
Robot working range
Recommended maximum ranges:
650 mm (TM5-700 model)
850 mm (TM5-900 model)
1150 (TM12)
1350 (TM14)
(Regarding the actual movement range, please refer to the 6DOF Workspace for the
respective user manual of each robot model.)
New object range:
the range robot selects new object (this range is executed in CVNewObj
node)
Working Area:
Actual work range, based on the intersecting boundaries of B Start and B End.
If there is no intersecting point, in the case that B Start is set to be small while B End is set to be
very large, the system will use the distance of range to determine the working area.
Robot Base:
Robot placement position.