TM Conveyor Tracking
Software version: TMflow 1.76
18
4.1.3 Advanced setting
Advanced Setting is used for setting conveyor object compensation. Description is as follows:
Conveyor Vector Compensate
(Calibration Point 2
)
X offset (mm)
: when adjusting calibration,
the calibration plate x direction error.
Y offset (mm)
: when adjusting calibration,
the calibration plate y direction error.
Z offset
: when adjusting calibration, the
calibration plate Z direction error.
(Based on Robot Base coordinates,
correct the X/Y/Z offset of Calibration
Point 2 coordinates)
Maximum object moving distance in a
frame (ETH Mode only):
this function
prevents a single object from being
detected as multiple objects.
•
If a single object is detected as
multiple objects, increase the value.
•
If multiple objects are detected as a
single object, decrease the value.
Figure 9 Advanced Setting
NOTE:
When executing Conveyor Tracking project, click “View Page” from the drop-down
menu on the top-left corner of TMflow and click “Conveyor Data” to adjust Advanced
Setting.
Advanced Setting does not support Warp Node project switching. If your project
would use Warp Node, remember to set Advanced Setting first and then use Warp.