n
L7-07: Torque Limit Control Method Selection during Accel/Decel
Selects the function of torque limit during acceleration and deceleration.
No.
Name
Setting Range
Default
L7-07
Torque Limit Control Method Selection during Acceleration/
Deceleration
0 or 1
0
Setting 0: Proportional Control
The torque limit function works with P-control during acceleration and deceleration and switches to I-control at constant
speed. Use this setting when acceleration or deceleration to the desired speed has priority over torque limitation during
speed changes.
Setting 1: Integral Control
The torque limit function always uses I-control. Use this setting when high accuracy torque limitation is required even
during speed changes. Using this function may increase the acceleration time, or may prevent the motor speed from reaching
the frequency reference when the torque limit is reached before.
u
L8: Hardware Protection
n
L8-01: Internal Dynamic Braking Resistor Protection Selection (ERF type)
This parameter selects the dynamic braking resistor protection when using an optional heatsink mounted braking resistor
(ERF type, 3% ED).
No.
Name
Setting Range
Default
L8-01
Internal Braking Resistor Protection
0 or 1
0
Setting 0: Disabled
Disables the braking resistor protection. Use this setting for any braking option other than the OYMC ERF Type resistor.
Setting 1: Enabled
Enables the protection for ERF type resistors.
n
L8-02: Overheat Alarm Level
Sets the overheat alarm (oH) detection level.
The drive will output an alarm when the heatsink temperature exceeds the alarm level set in parameter L8-02. If the
operation when this alarm occurs is set for continued operation (L8-03 = 4) and the temperature reaches the overheat fault
level, the drive will trigger an oH1 fault and stop the operation.
When an output terminal is set for the oH pre-alarm (H2-01/02/03 = 20), the switch will close when the heatsink temperature
rises above L8-02.
No.
Name
Setting Range
Default
L8-02
Overheat Alarm Level
50 to 130 °C
Depending on size
n
L8-03: Overheat Pre-Alarm Operation Selection
Sets the operation when an overheat pre-alarm is detected.
No.
Name
Setting Range
Default
L8-03
Overheat Pre-Alarm Operation
0 to 4
3
Setting 0: Ramp to Stop
If an overheat alarm occurs, the drive decelerates to stop using the selected deceleration time. If a digital output is
programmed for “fault” (H2-01/02/03 = E), this output will be triggered.
Setting 1: Coast to Stop
If an overheat alarm occurs, the drive switches off the output and the motor coasts to stop. If a digital output is programmed
for “fault” (H2-01/02/03 = E), this output will be triggered.
Setting 2: Fast-stop
If an overheat alarm occurs, the drive decelerates to stop using the Fast-stop time (C1-09). If a digital output is programmed
for “fault” (H2-01/02/03 = E), this output will be triggered.
Setting 3: Alarm Only
If an overheat alarm occurs, an alarm is output and the drive continues operation.
5.8 L: Protection Functions
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
203
5
Parameter Details
7/16/2008-13:23