6.7 Auto-Tuning Fault Detection
Auto-Tuning faults are shown below. When the following faults are detected, the fault is displayed on the Digital Operator
and the motor coasts to a stop. No fault or alarm outputs will occur
u
Auto-Tuning Codes, Causes, and Possible Solutions
Table 6.12 Auto-Tuning Codes, Causes, and Possible Solutions
LED Operator Display
Error Name
End1
Excessive V/f Setting. Detected only during Rotational Auto-Tuning, and displayed after Auto-Tuning is
complete.
Cause
Possible Solutions
The torque reference exceeded 20%
during Auto-Tuning.
• Before Auto-Tuning the drive, verify the information written on the motor nameplate and enter that
data to T1-03 through T1-05.
• Enter proper information to parameters T1-03 to T1-05 and repeat Auto-Tuning.
• If possible, disconnect the motor from the load and perform Auto-Tuning.
The results from Auto-Tuning the no-load
current exceeded 80%.
LED Operator Display
Error Name
End2
Motor Iron-Core Saturation Coefficient. Detected only during Rotational Auto-Tuning and displayed after
Auto-Tuning is complete.
Cause
Possible Solutions
Motor data entered during Auto-Tuning
was incorrect.
• Motor data entered to the T1 parameters does not match the information written on the motor nameplate.
• Restart Auto-Tuning and enter the correct information.
Auto-Tuning calculated values outside the
parameter setting range, assigning the
iron-core saturation coefficient (E2-07,
-08) a temporary value.
• Check and correct faulty motor wiring.
• Disconnect the motor from machine and perform Rotational Auto-Tuning.
LED Operator Display
Error Name
End3
Rated Current Setting Alarm (displayed after Auto-Tuning is complete)
Cause
Possible Solutions
• The motor line-to-line resistance and
the motor-rated current are not
consistent with one another.
• The correct current rating printed on the
nameplate was not entered into T1-04.
• Check the setting of parameter T1-04.
• Check the motor data and repeat Auto-Tuning.
LED Operator Display
Error Name
Er-01
Motor Data Error
Cause
Possible Solutions
Motor data or data entered during
Auto-Tuning was incorrect.
• Check that the motor data entered to T1 parameters matches motor nameplate input before Auto-Tuning.
• Start Auto-Tuning over again and enter the correct information.
Motor output and motor-rated current
settings (T1-02 and T1-04) do not match.
• Check the drive and motor capacities.
• Correct the settings of parameters T1-02 and T1-04.
Motor output and no-load current settings
(T1-04 and E2-03) do not match. Data
required when Auto-Tuning for OLV
Control or Stationary Auto-Tuning.
• Check the motor-rated current and no-load current.
• Correct the settings of parameters T1-04 and E2-03.
Base frequency and base motor rotations
(T1-05 and T1-07) do not match.
Set T1-05 and T1-07 to the correct value.
LED Operator Display
Error Name
Er-02
Minor Fault
Cause
Possible Solutions
Incorrect motor data entered during
Auto-Tuning.
• Motor data entered to the T1 parameters does not match the information written on the motor nameplate.
Enter the correct data.
• Start Auto-Tuning over again and enter the correct information.
The wiring is faulty.
• Check the wiring and correct defective connections.
• Check around the machine.
• Check the load.
Load is too heavy.
LED Operator Display
Error Name
Er-03
STOP Button Input
Cause
Possible Solutions
Auto-Tuning canceled by pressing STOP
button.
Auto-Tuning did not complete properly and will have to be performed again.
LED Operator Display
Error Name
Er-04
Line-to-Line Resistance Error
Cause
Possible Solutions
Motor data entered during Auto-Tuning
was incorrect.
• Motor data entered to T1 parameters does not match motor nameplate. Enter the correct data.
• Start Auto-Tuning over again and enter the correct information.
Auto-Tuning did not complete within
designated time frame.
• Check and correct faulty motor wiring.
• Disconnect the motor from machine and perform Rotational Auto-Tuning.
Drive-calculated values outside parameter
setting range.
6.7 Auto-Tuning Fault Detection
250
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
7/16/2008-13:23