100
Section
5
Specifications
and External
Di
mension
V400-R1CF/R1CS
User’s Manual
Section 5
Appendix
Specifications and External Dimension
Specifications
General specification
Applicable
codes
Bar code
JAN/EAN/UPC (A, E), CODE39, NW-7, ITF
Industrial2of5, CODE93, CODE128 (including EAN128), RSS
2D code
DataMatrix (ECC200), QR Code, Micro QR Code, PDF417, RSS
Number of reading digits No upper limit (depends on bar width and reading distance)
Reading
performance (*)
Light source
Four red LEDs (wave length: 630 nm)
Aiming light
Two green LEDs (wave length: 527 nm)
Minimum resolution
0.1 mm (bar code), 0.169 mm (2D code)
Image capture device
CMOS area sensor (1280 (H) x 1024 (V))
Working distance (WD)
60 mm
Field of view
52 x 41 mm (for WD = 60 mm)
Skew angle
-50 to 0
°
, 0 to +50
°
Pitch angle
-50 to 0
°
, 0 to +50
°
Tilt angle
360
°
Reading of bar codes on
curved surfaces
R > 15 mm (JAN8), R > 20 mm (JAN13)
Interface
Communication
specification
RS-232C
OK/NG outputs
NPN open collector output
Function setting
method
Menu sheet reading method or host command method
Functional
specifications
Reading trigger
External trigger (Transistor input)
Trigger by command (RS-232C)
Trigger a test reading by pressing the SCAN button on the product
OK/NG signals
OK signal is turned on to indicate a successful read
OK signal is turned on to indicate a successful read of registered label
NG signal is turned on to indicate a successful read of a non-registered
label
Indication LED
OK LED (green) illuminates to indicate a successful read
NG LED (red) illuminates for failed reading with an error message
output
Buzzer
Notifies a successful reading with a buzzer sound (Muting available)
Power supply
specification
Power voltage
4.5 to 5.5 VDC
Consumption current
During operation: 500 mA or less; during standby: 300 mA or less
Environmental
specifications
Ambient temperature
At operation: 0 to + 45
°
C; At storage: 2 to + 60
°
C
Ambient humidity
At operation and storage: 20 to 85% RH (with no icing or condensation)
Ambient atmosphere
No corrosive gases
Ambient light resistance 10,000 lx (fluorescent lamp), 100,000 lx (sunlight)
Vibration resistance
12 to 100 Hz, 19.6 m/s
2
(2G), 1 hour each in three directions
Degree of
protection
IP54 (IEC60529)