Introduction Procedure
Inputting a command from the upper equipment
1.
Transmit the command character strings of the function you want to set.
Menu Sheet/Command List p.56
2.
Transmit the command “Z2” to write the setting data in the nonvolatile memory of the
reader.
Transmission method of the command by designating values and characters is
explained as follows.
E.g.: Setting “AB” on header (Designating codes directly)
Be sure to write the setting data in the nonvolatile memory whenever a condition is set by inputting a
command from the upper equipment. When you turn the power OFF without writing the setting in the
memory, the settings will be lost.
SCAN
OKING
Transmits command character strings
Multi-code reader
V400-R1CF/R1CS
Upper equipment
Command
Header setting
command
Character
“A”
Character
“B”