Setting Method
Setting for the number of times of reading
coincidence
When reading result coincides the number of times you have set, the reading result is
output to the RS-232C interface.
The verification system is AND verification (Continuous coincidence system). (This
cannot be changed.)
Setting for reading operation
The reading operation is set.
Menu sheet
Command
Reading once and verification zero times
_X0_
X0
Reading twice and verification once (Factory default setting)
_X1_
X1
Reading three times and verification twice
_X2_
X2
Reading four times and verification three times
_X3_
X3
Menu sheet
Command
Single reading (Factory default setting)
_S0_
S0
Plural reading
_S1_
S1
Continuous reading
_S2_
S2