72
Section
4
Menu Sheet/Command
L
ist
V400-R1CF/R1CS
User’s Manual
Section 4
Setting Method
Setting for failed reading
Process for failed reading is set.
With the factory default setting, nothing is transmitted in the event of failed reading.
Error message - No label
Direct input characters of up to 4 digits can be set. These characters are transmitted
when no code (label) is detected during the reading time.
Error message - Decoding failure
Direct input characters of up to 4 digits can be read. These characters are transmitted
when a code (label) is detected during the reading time but nothing is read.
E.g.: In the following two examples, the “NL<CR>” message is set for “No label” and the “ND<CR>” message
for “Decoding failure”. Those two examples may occur at the same time.
• The error message is disabled when no direct input characters are read after the command.
• This may be output simultaneously with “Error message - Decoding failure”.
• The error message is disabled when no direct input characters are read after the command.
• This may be output simultaneously with “Error message - No label”.
Menu sheet
Command
Error message - No label
_TH_
TH
Setting start (ZZ)
Error - No label (TH)
N (0N)
L (0L)
<CR> (1M)
Setting end (ZZ/Z2)
Setting start (ZZ)
Error - Decoding failure (TI)
N (0N)
D (0D)
<CR> (1M)
Setting end (ZZ/Z2)
When no code is detected
during the reading time
When a code is detected during
the reading time but nothing is
read