I-13
Appendices
V440-F C-Mount Code Reader User Manual
I-7 ISO/IEC 15416
S
y
mbo
l Qualit
y Ou
tp
ut
I
I-7-4
Decode
Definition:
Decode is calculated and graded for each scan and provided for the
overall grade calculation in accordance with the ISO 15416 specifica-
tion. The parameter grade and value provided for output is an average
value for each measured scan over the entire symbol.
When enabled, the Decode is attached to the symbol output data as a
value.
Serial Cmd:
<
K726
,
aperture,overall,edge determination,
decode
,contrast,minimum
reflectance,minimum edge contrast,modulation,defects,decodability,quiet
zone
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
I-7-5
Contrast
Definition:
Contrast measurements assume 8-bit, 0 to 255 grey correlate to 0 to
100% reflectance. Contrast is calculated and graded for each scan and
provided for the overall grade calculation in accordance with the ISO
15416 specification. The parameter grade and value provided for out-
put is an average value for each measured scan over the entire symbol.
When enabled, the Contrast is attached to the symbol output data as a
value.
Serial Cmd:
<
K726
,
aperture,overall,edge determination,decode,
contrast
,minimum
reflectance,minimum edge contrast,modulation,defects,decodability,quiet
zone
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
I-7-6
Minimum Reflectance (Reflectance Min)
Definition:
The Minimum Reflectance (Reflectance Min) is calculated and graded
for each scan and provided for the overall grade calculation in accordance
with the ISO 15416 specification. The parameter grade and value provided
for output is an average value for each measured scan over the entire
symbol.
When enabled, the Minimum Reflectance is attached to the symbol output
data as a value.
Serial Cmd:
<
K726
,
aperture,overall,edge determination,decode,contrast,
minimum
reflectance
,minimum edge contrast,modulation,defects,decodability,
quiet zone
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
I-7-7
Minimum Edge Contrast
Definition:
Contrast measurement assume 8-bit 0 to 255 grey correlate 0 to 100%
reflectance The Minimum Edge Contrast is calculated and graded for
each scan and provided for the overall grade calculation in accordance
with the ISO 15416 specification. The parameter grade and value pro-
vided for output is an average value for each measured scan over the
entire symbol.
When enabled, the Minimum Edge Contrast is attached to the symbol
output data as a value.
Serial Cmd:
<
K726
,
aperture,overall,edge determination,decode,contrast,minimum
reflectance,
minimum edge contrast
,modulation,defects,decodability,
quiet zone
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Summary of Contents for V440-F
Page 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Page 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Page 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Page 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Page 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Page 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Page 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Page 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Page 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Page 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Page 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Page 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Page 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Page 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...