L-5
Appendices
V440-F C-Mount Code Reader User Manual
L-4 C
o
n
figu
ratio
n Dat
abase
Statu
s
L
L-
4-1
Index
L-4 Configuration Database Status
Note:
The Exposure parameter is read-only when the reader is in
Continuous Read
mode.
Important:
Pixel Binning has no effect when the
Image Dimension
mode is configured as
Region of
Interest
in the
Database Mode
command. This is because the
Window of Interest
reader settings are
determined by the software based on the
Region of Interest
setup. There is no benefit to Pixel Binning
to increase processing speed when ROI is configured, because the frame size would need to be
increased to make Pixel Binning possible.
L-4-1
Index
Usage:
Useful for applications that require several different complex reader configurations
to be applied sequentially. Multiple database indexes allow you to concatenate
configuration profiles, and to perform more complex operations than would
be possible with only one set of configuration parameters.
Definition:
Determines the specific database index that will be used.
Serial Cmd:
<
K255,
index
,exposure,gain,focal distance,pixel binning,row pointer,column
pointer,row depth,column width,symbology,morphology operator,morphology
size,tray id,matrix id
>
Options:
1 to 10
L-4-2
Exposure
Serial Cmd:
<
K255,
index,
exposure
,gain,focal distance,pixel binning,row pointer,column
pointer,row depth,column width,symbology,morphology operator,morphology
size,tray id,matrix id
>
Default:
2500
Options:
50 to 100,000
L-4-3
Gain
Serial Cmd:
<
K255,
index,exposure,
gain
,focal distance,pixel binning,row pointer,column
pointer,row depth,column width,symbology,morphology operator,morphology
size,tray id,matrix id
>
Default:
0
Options:
0 to 100
L-4-4
Focal Distance
Definition:
Provides the focal distance adjustment for the reader.
Any value outside this range will be rejected.
If you attempt to set the Focal distance as the out of range value of your
model, the parameter will be left as-is.
Serial Cmd:
<
K255,
index,exposure,gain,
focal distance
,pixel binning,row pointer,column
pointer,row depth,column width,symbology,morphology operator,morphology
size,tray id,matrix id
>
Default:
102
Options:
25 to 4,000 (mm)
100 to 4,000 (1/100 inch)
L-4-5
Pixel Binning
Serial Cmd:
<
K255,
index,exposure,gain,focal distance,
pixel binning
,row pointer,column
pointer,row depth,column width,symbology,morphology operator,morphology
size,tray id,matrix id
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Summary of Contents for V440-F
Page 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Page 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Page 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Page 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Page 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Page 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Page 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Page 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Page 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Page 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Page 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Page 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Page 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Page 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...