107
V500-R2 series
User’s Manual
Sec
tion
5
How to Use Command
L
in
k
Un
it
V7
00-
L1
2
Section 5
Example of System Configuration
General specification
Communication function
DIP-SW is used for setting each function.
Item
Specification
Number of connected antenna
set
1
Power voltage
24 VDC + 10 % -15 %
Power consumption
10 W or less
Insulation resistance
50 mM ohm or more (at 500 VDC mega), between power terminal bulk
blocs and ground terminals
Withstand voltage
100 VAC (50/60 Hz, 1 min), apply to power terminals and ground
terminals, and leak current must be 5 mA or less
Resistance to vibration
10 to 150 Hz, double amplitude 0.20 mm, vibration with acceleration of
15 m/s2, at each X, Y, Z direction
8 min. each, 10 sweeps applied, without abnormal
Impact resistance
Apply shock with acceleration of 150 m/s2, 3 times for each X, Y, Z
direction, total 18 times, without abnormality.
Ambient temperature
At operation: 0 to +45 °C
At storage: -15 to +50 °C (without freeze or dew condensation)
Ambient humidity
At operation and storage: 35 to 85 % RH (without due condensation)
Enclosure rating
IP20 (IEC60529 Standard)
Ground
D type grounding (former type 3 grounding)
Mass
Approx. 185 g
Item
Specification
Machine No.
01 to 31
Communication speed with the
upper equipment
48000/9600/19200/38400 bps
Data transmission procedure to
the upper equipment
Normal procedure (polling procedure)
• When inputting data from the upper equipment, it outputs to the ID port
immediately and transmits received reply to the upper equipment.
• When inputting data from the ID port, it waits for the inquire command
and transmits data.
• In case of 1: N connection, this procedure is recommended.
Through procedure (immediate transmission system)
• When inputting data from the upper equipment, it outputs to the ID port
immediately. It does not transmit the received reply to the upper
equipment.
• When inputting data from the ID port, it transmits to the upper
equipment immediately.
RS-485 termination resistance
OFF (invalid)
ON (valid)