SECTION 3
Functions
Setting Operating Parameters
The operating parameters outlined below can be set to optimize CF Reader/Writer performance and reliability,
and to optimize the system itself. If changing the operating parameters, always do so with the power turned
ON. Normally, there are no problems in using the default settings.
•
Auto command abort time
•
Write verification
The CF Reader/Writer is initialized when the power is turned OFF and the operating parameter settings are not stored.
for information on using the Parameter Setting (SP) command.
Auto Command Abort Time
When an Auto command is received, the CF Reader/Writer waits until a Tag is detected in the
communications area and then starts communications. If, however, a Tag is not detected within a set
period, processing is aborted and a No Tag error (72) is returned.
A command error will be returned if "00" is set as the Abort auto command time.
* The default setting is 10 s.
Write Verification
Write verification checks that any data written to Tags is correct. A verification error (71) will be
returned if the data is not written correctly.
* The default setting is 1 (write verification enabled).
for information on how to use the Parameter Setting (SP) command.
Setting range
01 to 60 s
Setting range
0 (write verification disabled)
1 (write verification enabled)
CF Reader/Writer to Tag
Tag to CF Reader/Writer CF
Reader/Writer to Host
External input
Trans-
mission
Response
Auto command abort time
Error 72