49
RFID System
User's Manual
Section 2
Se
tt
in
g the
Ha
nd-h
e
ld Re
ade
r/Wr
it
e
r
Section 2
Communications Preparations
Setting the Hand-held Reader/Writer
Settings
The following settings are used to operate the Hand-held Reader/Writer.
• Serial communications parameters (baud rate, transmission code, parity check, stop bits)
• Basic function settings (Auto Command OFF)
These settings can be changed by sending a setting command from the host device. To operate the
Hand-held Reader/Writer with the new setting, the power must be turned OFF then ON again, or the
ABORT command must be used.
Serial Communications Parameters
The following settings are related to serial communications. Use the COMMUNICATIONS CONDI-
TIONS SETTING (TR) command.
Note: Items marked by an asterisk (*) are set as the default when shipped from the factory.
Basic Function Settings
The Auto Command OFF function can be set. Use the BASIC FUNCTIONS SETTING (FN) command.
Note: Items marked by an asterisk (*) are set as the default when shipped from the factory.
Reading the Settings
Use the SET INFORMATION READ (UL) command to read the settings of the Hand-held Reader/
Writer. The information read by the SET INFORMATION READ command is set in the backup memory
of the Hand-held Reader/Writer. For this reason, care must be taken when the power is first turned ON
after the settings have been changed because the operational settings of the Hand-held Reader/Writer
will be different.
Item
Contents
Baud rate (bps)
2,400, 4,800, 9,600*, 19,200, 38,400
Transmission code
7-unit ASCII 7* or 8-unit JIS 8
Parity check
Even parity*/odd parity/none
Stop bits
2*/1
Item
Contents
Auto Command OFF function
Yes (1 minute)*, No