(1)Environment 

Do not expose V690-HMG01 to explosive gas, inflammable gas, 
corrosive gas, metallic powder, dust particlesetc, etc. 

(2)Water-tight 

This product is not water-tight. 
V690-HMG01 may malfunction, suffer damage, or burn, in 
places where they may be exposed to water, oil, medicines, or 
organic solvent. 

(3)Enclosure of the product 

Do not remove the casing of this product. Otherwise, the 

product may malfunction forever. 

Specifications

General specification

Indicator

Performance specifications

Power supply

Ambient temperature

Ambient humidity

Specifications

24V DC 

10% / 

15%

20 to 

60

with no icing

35 to 85%

with no condensation

Item

Transmission Frequency

2434.25

2465.75MHz

Emission power

10mW

ID System Read/Write Antenna 

Model

V690-HMG01A

2

3

4

C

H

T

Red

Yellow

Green

1

Name

P

Meaning

Green

No

Specification

Item

Vibration resistance

Enclosure rating

Setup method
Weight

Durable at 10 to 150Hz
Double amplitude less than 0.7mm
10 sweeps for 8 minutes each in 3 directions.

IP62
(when placing the connector side down)

Mounting on DIN rail or fixed with M5 screws
About 2.6Kg

Shock resistance

150m/s

2

, 3 times in 6 directions

Cable length

0.5m with a watertight connector

Dielectric strength

1000V AC 50/60Hz for 1 min
Between cable terminals and case

Insulation resistance

 20 M

Ω

 min. (at 100V DC ) 

Between cable terminals and case

Dimensions

Remains lit when the power is turned on

Lit when the antenna sends an elec tromagnetic wave

Lit when the antenna sends the data to a Host computer

Lit when the antenna sends the data to a tag

Applied standards

R&TTE / FCC Part15 Subpart C

PRECAUTION FOR CORRECT USE

(1)Do not use it in the following environment.

Places where the temperature varies heavily.

Places where the humidity is high and it condenses. 

Where the antenna may get splashed with water, oil, chemicals 

or organic solvents.

Where the antenna is exposed to corrosive gases. 

Where a noise-generating source is nearby. 

 (2) Installation 

Avoid setting up the unit near a highly heat-generating device 

(such as heater, transformer and large-capacity resistor). 

Tighten the M5 mounting screws to a smaller torque than 2.3 

N

m. Do not apply screw loctite and any other organic solvent 

to any other parts than the screws. The casing may get cracked. 

(3)Cleaning 

Be sure to use the market alcohol and benzene. 

Do not use the thinner. 

(4)Be sure to connect the grounding. 

If the grounding is not connected, the read/write antenna may fail 
to function.

260.3

280

260.3

280

260.3

40

28

MOUNTING SCREW HOLES

28

19

24

INDICATORS

CONNECTOR

BUSH

VINYL INSULATED ROUND CORD 7.5dia.
12 CORES LENGTH 0.5M

21

260.3

4-M5

4-6dia.
MOUNTING HOLES

20dia.

23dia.

60

FERRITE CORE

OMRON Corporation

Suitability for Use

EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0  Fax: 49-7032-811-199

NORTH AMERICA
OMRON ELECTRONICS  LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A
Phone:1-847-843-7900 Telephone Consultation
1-800-55-OMRON    Fax : 1-847-843-7787

ASIA-PACIFIC
OMRON ASIA PACIFIC PTE LTD
83 Clemenceau Avenue,#11-01 UE Square,Singapore 239920
Phone : 65-6-835-3011 /Fax :65-6-835-2711

n

THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.  
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF 
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY 
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or 
regulations that apply to the combination of the products in the customer's 
application or use of the product. 
 
Take all necessary steps to determine the suitability of the product for the 
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.

LAWS AND STANDARDS

1

United States

FCC  Part15 Subpart C
FCC ID: E4E6CYCIDV6900101

This device complies with part 15 of the FCC Rules. 
Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including 

interference that may cause undesired operation.

Select only with "Low Power Mode(2m mode).

Default Setting is "Low(2m mode)."

The use of "High power mode (5m mode)" is not allowed 
by FCC.
whose rule has penalty clause.

2. Europe

EC/R&TTE Directive

Radio and Telecommunication

Terminal Equipment Directive 1999/5/EC

The V690 is allowed to use:
Austria, Belgium, Denmark, Finland, France, Greece,
Iceland, Ireland, Italy, Luxembourg, Netherlands,
Norway, Spain, Switzerland, UK. 

Select only radio wave channel"5". Do not use theV690 in the 

other channels.

Default Setting is "5."

To use V690 in channels except channel 5 is not allowed by 
Radio lows of each country, which may have penalty clause.

3. For the use in other countries

Please contact our sales representatives.

Color

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet pri-

marily describes precautions required in installing and

operating the product.

Before operating the product, read the sheet thoroughly to

acquire sufficient knowledge of the product. For your con-

venience, keep the sheet at your disposal.

Reviews: