6-6
Section
Functions
103
6-6-1 Functions of the Programming Console
MONITOR mode
RUN mode
PROGRAM mode
Set data
Read and write data
Communications
test
Ambient noise
check
Latest error log
Statistical error log
Set data
Operation
Read
Write
Execute TEST
READ
Execute TEST
READ
MONITOR Mode
•
Set Data Display
Displays data that is set with the DIP switch of the Controller.
•
Read and Write Data
Reads and writes data from and to ID Tags at a standstill in the communica-
tions area of the Antenna.
•
Communications Test
Tests communications with ID Tags moving in the communications area.
•
Ambient Noise Check
Checks the ambient noise of the Antenna location. The present, average, mini-
mum, and maximum values of noise are displayed along with the elapsed time.
•
Latest Error Log
Displays up to 30 errors in descending order starting from the most recent one.
•
Statistical Error Log
Classifies all errors recorded after the Controller starts operating according to
the response code and displays the number of each type of errors.
RUN Mode
•
Set Data Display
Displays data that is set with the DIP switch of the Controller.
•
Operation Monitor
Displays the commands and responses the Controller receives in real time.
The V700-CD1D Controller does not operate in PROGRAM mode.
PROGRAM Mode
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr