4-1
Section
Controller
43
DIN Track Mounting
DIN track
Closed mounting
End plate
Mounting hook
Note Take the height of the DIN track into
consideration at the time of mounting.
DIN track (1 m long)
OMRON PFP-100N2 is
recommended.
Height: 80 mm max.
(1) Hook the Controller to part A. Then
press the Controller in direction B
to mount the Controller.
(2) Pull the mounting hook down-
wards. Then lift the Controller up-
wards to disconnect the Controller.
PFP-100N2 DIN Track
PFP-M End Plate
(See note)
4-1-4 Connection and Disconnection of Antenna Connector
A single antenna can be connected to the Controller through the V700-A4
j
An-
tenna Cable (sold separately), the standard length of which is 30 m maximum.
Two Antenna Cables can be connected up to a total length of 50 m. The Antenna
is provided with a 0.1-m-long cable. Therefore the length between the Antenna
and Controller is 50.1 m in this case.