4-1
Section
Controller
55
Use the following procedure to prepare and connect the communications con-
nectors.
1, 2, 3...
1. Attach crimp terminals to the stripped ends of the communications wires.
Check the alignment of the connector and insert the wires into the correct
holes in the connector.
•
Recommended Cable: MVVS 4CX0.5Sq
Use two of the cable’s wires as the RS-485 interface lines and the other
two wires as the SYNC lines. Connect the shield wire to the ground termi-
nal. See Wiring SYNC Signals on page 48 for details.
•
Recommended Terminals: Nihon Weidmuller H-sleeve Series
Crimp terminal
Wire
Insert the wire into the pin terminal and crimp it. Nihon Weidmuller sells the
PZ-series Crimping Tool for crimping these terminals.
2. Tighten the connector’s set screws to secure each of the wires in the con-
nector. A regular screwdriver that tapers at the end may not fit into the screw
hole, so use a screwdriver with a tip and shaft that are the same width. Tight-
en the screws to a proper torque (about 0.5 N
@
m).
Precision flat-blade
screwdriver that does
not taper at the tip.
OMRON sells the following
screwdriver that is ideal for
this application.
Side
Face
0.6 mm
3.5 mm
Preparing and Installing
Connectors
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr