5-7
Setting Command
5-7
5-55
5-7-6 Node Number Setting(NN)
This command sets and reads the node number of the Reader/Writer.
<Command
Format>
STX
Node No.
Command
code
"NN"
Node number
change
specification
ETX BCC
1 2
2
2 1
1
Node number
change
specification
Specifies the node number in decimal that you want to change.
Specification range: 00 to 31, **
When “**” is specified, the Reader/Writer reads the current setting.
<Response
Format>
STX Node
No. Retry
flag
Command
code
"NN"
Response
code
"00"
Node number ETX BCC
1 2 1 2
2
2 1
1
Response code
00: Normal completion
For other Response Codes, refer to SECTION 5-3-7 Response Code List.
Node number
Indicates the specified node number in decimal.
:・
The setting is enabled after reset by the Reset Command(XZ). To enable the setting forthe
next start-up, the setting must be saved by Set Value Writing (EW).