5-7
Setting Command
5-7
5-58
5-7-8 Communications Type Setting (CT)
This command selects whether COM1 will be used as RS-232C or RS-485.
<Command
Format>
STX
Node No.
Command
code
"CT"
Commni
cations
type
ETX BCC
1 2 2 1 1
1
Specify the number corresponding to the communications type that
you want to select.
Specification range: 0, 1, *
When “*” is specified, the Reader/Writer reads the current setting.
Specification
number
0 1
*
Communications
type
Communicati
ons type
RS-232C RS4-85
-
<Response
Format>
STX Node
No. Retry
flag
Command
code
"CT"
Response
code:
"00"
Commun
ications
type
ETX BCC
1 2 1 2
2 1
1
1
Response code
00: Normal completion
For other Response Codes, refer to SECTION 5-3-7 Response Code List.
Terminal setting
Indicates the number corresponding to the specified terminal resistance.
:・
The setting is enabled after reset by the Reset Command(XZ). To enable the setting forthe
next start-up, the setting must be saved by Set Value Writing (EW).
5-7-9 Tag Communications Mode Setting(CM)
This command sets and reads the communications mode for use in communications with Tags.
<Command
Format>
STX
Node No.
Command
code
"CM"
Commni
cations
mode
ETX BCC
1 2
2 1
1
1
Specify the number corresponding to the communications mode that
you want to select for communications with Tags.
Specification range: 0, 1, *
When “*” is specified, the Reader/Writer reads the current setting.
Specification
number
0 1
*
Communicatio
ns mode
Tag
communications
mode
Standard
Mode
Fast Mode
-
<Response
Format>
STX Node
No. Retry
flag
Command
code
"CM"
Response
code:
"00"
Communi
cations
mode
ETX BCC
1 2 1 2
2 1 1
1
Response code
00: Normal completion
For other Response Codes, refer to SECTION 5-3-7 Response Code List.
Communications
mode
Indicates the number corresponding to the specified terminal
resistance.
:・
The setting is enabled after reset by the Reset Command(XZ). To enable the setting forthe
next start-up, the setting must be saved by Set Value Writing (EW).