Firmware Upgrade Page
1. Click
the
Firmware
link on the navigation
menu. The
Firmware Upgrade
page appears.
2. Place the cursor in the Filename field and type
the complete network pathname of the
firmware file or click the
Browse
button to
locate the new firmware file.
3. Click
the
Upgrade
button to download the new
firmware to the Reader.
The status frame at the bottom of the page
displays the progress of the upgrade if the web
browser supports automatic page reload. Click
the
Refresh
button to update the status bar if
the web browser does not support automatic
page reload.
Downloaded firmware IS NOT implemented
until the Reader is restarted.
If an error occurs during the firmware upgrade,
use Safe Mode to recover.
Restart Page
Use the Restart page to restart the Reader.
1. Click the Restart link on the navigation menu;
The Restart Reader page appears.
2. To restart the Reader, click the
Restart
System
button. The following dialog boa
appears.
3. Click
OK
. The following message appears and
remains on the screen until the Reader
restarts. Then the Status page appears.
Diagnostics
Page
The diagnostics page provides a wealth of
information, including the current settings of the
Reader, comprehensive version information, and
current status of network interfaces.