background image

351

Varispeed J7

CIMR-J7AZ

Varispeed J7

Small, simple and smart

• V/f controlled inverter
• Compact size
• Good torque performance: 100% torque at 1.5 Hz, 

150% at 3 Hz

• 150% overload / 60sec
• Overload detection function.
• Motor thermal function
• Freely configurable V/f curve
• 4 programmable digital input
• 1 programmable digital output
• 1 programmable analog output
• Optional RS-232C/485 communication - Modbus
• PC Configuration tool: CX-drive
• CE, UL, and cUL marking

 
Ratings

• 200 V class single-phase 0.1 to 1.5 kW
• 200 V class three-phase 0.1 to 4.0 kW
• 400 V class three-phase 0.2 to 4.0 kW

System configuration

SI-232/J7
SI-232/J7C

SI-485/J7

3G3IV-PCN329-E
Inverter to PC cable

3G3IV-PCN126/326
Digital operator
extension cable

3G3IV-PEZZ8122_
DIN attachment

JVOP-144
Remote digital oper.
with potentiometer

CX-Drive

Line filter

Varispeed
J7

JVOP-146
Remote digital oper.
with potentiometer

Y203-EN2-02-Katalog.book  Seite 351  Mittwoch, 24. Mai 2006  2:22 14

Summary of Contents for VARISPEED J7 -

Page 1: ...analog output Optional RS 232C 485 communication Modbus PC Configuration tool CX drive CE UL and cUL marking Ratings 200 V class single phase 0 1 to 1 5 kW 200 V class three phase 0 1 to 4 0 kW 400 V...

Page 2: ...1 1 1 9 3 0 4 2 6 7 0 9 1 4 2 6 3 7 4 2 5 5 7 0 Rated output current A 0 8 1 6 3 5 8 11 17 5 1 2 1 8 3 4 4 8 5 5 7 2 9 2 Max output voltage V 3 phase 200 to 230 V proportional to input voltage Single...

Page 3: ...raking current at stop start 50 of inverter rated current 0 5 sec or less frequency reference bias gain fault retry speed search frequency upper lower limit setting overtorque detection frequency jump...

Page 4: ...s Selected function is lit see the functions below Its data is displayed on data display Operation key Press to run the motor The RUN light is ON while running Stop Reset key Press to stop the motor I...

Page 5: ...20P4 102 0 8 1 1 20P7 122 0 9 Fan cooled 1 5 21P5 2 108 129 96 118 1 3 2 2 22P2 154 1 5 4 0 24P0 140 161 128 2 1 200 V single phase 0 1 B0P1 1 68 128 70 56 118 5 0 5 Self cooled 0 2 B0P2 0 4 B0P4 112...

Page 6: ...E 169 111 50 135 156 91 5 3 M5 22 96 118 M4 3G3JV PFI3010 SE 169 111 50 135 156 91 5 3 M5 22 96 118 M4 3G3JV PFI3020 SE 174 144 50 135 61 120 5 M5 28 128 118 M4 Rasmi model Dimensions W H L X Y Invert...

Page 7: ...ZZ08122B CIMR J7AZ24P0 3G3IV PEZZ08122C Single phase 200 VAC CIMR J7AZB0P1 B0P2 B0P4 3G3IV PEZZ08122A CIMR J7AZB0P7 B1P5 3G3IV PEZZ08122B 3 phase 400 VAC CIMR J7AZ40P2 40P4 40P7 41P5 42P2 3G3IV PEZZ08...

Page 8: ...s 0 V common For a PNP transistor 24 V common a 24 V external power supply is necessary DC reactor option Forward run stop Reverse run stop External fault no contact Fault reset Multi step speed refer...

Page 9: ...8mA photocoupler isolation S2 Multi function input selection 2 Factory setting runs when CLOSED stops when OPEN S3 Multi function input selection 3 Factory setting fault reset S4 Multi function input...

Page 10: ...1 B0P2 B0P4 B0P7 B1P5 Inverter capacity kVA 0 3 0 6 1 1 1 9 3 0 Rated current A 0 8 1 6 3 0 5 0 8 0 Heat loss W Fin 3 7 7 7 15 8 28 4 53 7 Inside unit 10 4 12 3 16 1 23 0 29 1 Total heat loss 14 1 20...

Page 11: ...4 2 2 2 15 0 71 2 2 7 5 3 6 4 0 20 0 53 4 0 10 2 2 200 V class 400 V class Max applicable motor output kW Current value A Inductance mH Max applicable motor output kW Current value A Inductance mH 0...

Page 12: ...V 0 12 Kw 0 8 A CIMR J7AZB0P10 0 25 Kw 1 6 A CIMR J7AZB0P20 0 55 Kw 3 0 A CIMR J7AZB0P40 1 1 Kw 5 0 A CIMR J7AZB0P70 1 5 Kw 8 0 A CIMR J7AZB1P50 3x200 V 0 12 Kw 0 8 A CIMR J7AZ20P10 0 25 Kw 1 6 A CIMR...

Page 13: ...7 43P0 44P0 3G3JV PFI3020 SE 3G3JV PFI3020 E 20 15 1 0 Type Model Description Funtions Digital operator JVOP 146 Remote digital operator without potentiometer JVOP 144 Remote digital operator with pot...

Page 14: ...Description Installation Software CX drive Computer software Configuration and monitoring software tool for drives CX One Computer software Complete OMRON automation software including CX drive Type M...