Varispeed J7
361
AC reactor
DC reactor
200 V class
400 V class
Max. applicable
motor output kW
Current value
A
Inductance
mH
Max. applicable
motor output kW
Current value
A
Inductance
mH
0.1
2.0
2.0
------
0.2
2.0
2.0
0.2
1.3
18.0
0.4
2.5
4.2
0.4
0.75
5
2.1
0.75
2.5
8.4
1.5
10
1.1
1.5
5
4.2
2.2
15
0.71
2.2
7.5
3.6
4.0
20
0.53
4.0
10
2.2
200 V class
400 V class
Max. applicable
motor output kW
Current value
A
Inductance
mH
Max. applicable
motor output kW
Current value
A
Inductance
mH
0.12
5.4
8
--------
0.25
0.37
3.2
28
0.55
0.55
1.1
1.1
1.5
18
3
1.5
5.7
11
2.2
2.2
4.0
4.0
12
6.3
L1(R)
U
V
W
X
Y
Z
L2(S)
L3(T)
L1(R)
L2(S)
L3(T)
T1(U)
T2(V)
T3(W)
CIMR-J7AZ
MCCB
Motor
AC reactor
IM
Be sure to connect
AC reactor on inverter
input side [L
1
(R),
L
2
(S), L
3
(T)].
CIMR-J7AZ
⊕
⊕
DC reactor
Motor
MCCB
Y203-EN2-02-Katalog.book Seite 361 Mittwoch, 24. Mai 2006 2:22 14